Evidence map›Paper›PMID 42621993›Full record

ArticleInternational journal of dentistry2026

Effect of Undersized Drilling and Sequential Osseodensification on Primary Implant Stability in Simulated Bone Types III and IV: An In Vitro Study.

Silvio Yoshiaki Okagawa, Alex Sandro de Souza, Paulo Sérgio Perri de Carvalho, Antonio Scarano, Bruno Freitas Mello, Sergio Rexhep Tari, Gustavo Coura, Gustavo Vicentis Oliveira Fernandes, Sergio Alexandre Gehrke

Abstract read
In one paragraph

Article in International journal of dentistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Silvio Yoshiaki OkagawaDepartment of Implant Dentistry, SLMANDIC - Sao Leopoldo Mandic, Campinas 13045-755, Brazil, slmandic.edu.br.ORCID https://orcid.org/0009-0009-4728-3240
Alex Sandro de SouzaDepartment of Implant Dentistry, SLMANDIC - Sao Leopoldo Mandic, Campinas 13045-755, Brazil, slmandic.edu.br.
Paulo Sérgio Perri de CarvalhoDepartment of Implant Dentistry, SLMANDIC - Sao Leopoldo Mandic, Campinas 13045-755, Brazil, slmandic.edu.br.ORCID https://orcid.org/0000-0003-1775-3108
Antonio ScaranoDepartment of Innovative Technologies in Medicine & Dentistry, University of Chieti-Pescara, Chieti 66013, Italy, unich.it.ORCID https://orcid.org/0000-0003-1374-6146
Bruno Freitas MelloDepartment of Pharmaceutical Science, School of Health Sciences, Vale do Itajai University (UNIVALI), Itajai 88302-901, Brazil, univali.br.
Sergio Rexhep TariDepartment of Innovative Technologies in Medicine & Dentistry, University of Chieti-Pescara, Chieti 66013, Italy, unich.it.
Gustavo CouraDepartment of Implant Dentistry, SLMANDIC - Sao Leopoldo Mandic, Campinas 13045-755, Brazil, slmandic.edu.br.
Gustavo Vicentis Oliveira FernandesMissouri School of Dentistry and Oral Health, A.T. Still University, St. Louis 63104, Missouri, USA, atsu.edu.ORCID https://orcid.org/0000-0003-3022-4390
Sergio Alexandre GehrkeDepartment of Pharmaceutical Science, School of Health Sciences, Vale do Itajai University (UNIVALI), Itajai 88302-901, Brazil, univali.br.ORCID https://orcid.org/0000-0002-5863-9101

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Primary implant stability is a key factor for successful osseointegration and may be influenced by osteotomy preparation techniques, particularly in low-density bone. Thus, this study compared undersized drilling (UD), UD combined with osseodensification, and sequential osseodensification protocols with varying degrees of undersizing in simulated bone types III and IV with respect to implant stability. Additionally, the relationships between insertion torque (IT), removal torque (RT), and implant stability quotient (ISQ) were analyzed. Materials and Methods: Eighty implants (4.0 × 11 mm) were placed in polyurethane blocks simulating type III and IV bone with a cortical layer. Four osteotomy protocols were tested: UD, UD plus osseodensification (OD1), and sequential osseodensification with -0.5 mm (OD2) and -0.7 mm (OD3) undersizing. Primary stability was assessed using IT, RT, and ISQ measurements. Data were analyzed using two-way ANOVA, Pearson correlation, and multiple regression analysis ( Results: OD2 and OD3 produced higher IT values in both bone types compared with UD and OD1. In type III bone, OD3 showed the highest RT values, while in type IV bone, OD2 and OD3 were significantly higher than UD and OD1. ISQ values were higher for osseodensification protocols in type III bone, whereas no significant differences were observed in type IV bone. A strong correlation was found between IT and RT ( Conclusion: The use of sequential osseodensification protocols yielded superior mechanical stability parameters, specifically in IT and RT, in synthetic (polyurethane) bone models. However, improvements in ISQ were predominantly noted in the denser type III model. Importantly, because the tested protocols involved different drill designs and underpreparation dimensions, these enhancements reflect the success of the overall surgical strategy rather than the isolated effect of osseous densification.

Indexed as

implant stabilitylow-density boneosseodensificationpolyurethane modeltorqueundersized drilling

Identifiers

PMID42621993
PMCPMC13488456

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.