Evidence map›Paper›PMID 42620791›Full record

ArticleDigital health

Development and validation of a deep learning-based model for estimating stroke volume and blood pressures simultaneously using electrocardiogram and photoplethysmogram.

Hyun-Lim Yang, Seong-A Park, Hyeonhoon Lee, Chul-Woo Jung, Ho-Geol Ryu, Hyung-Chul Lee

Abstract read
In one paragraph

Article in Digital health. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Hyun-Lim YangDepartment of Biomedical Engineering, College of Medicine, Chungnam National University, Daejeon, Republic of Korea.ORCID https://orcid.org/0000-0003-2221-3042
Seong-A ParkDepartment of Critical Care Medicine, Seoul National University Hospital, Seoul, Republic of Korea.ORCID https://orcid.org/0009-0007-0241-6746
Hyeonhoon LeeDepartment of Transdisciplinary Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
Chul-Woo JungDepartment of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea.
Ho-Geol RyuDepartment of Critical Care Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
Hyung-Chul LeeHealthcare AI Research Institute, Seoul National University Hospital, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0003-0048-7958

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Cardiac output (CO) is essential for systemic oxygen delivery, but gold-standard measurement using pulmonary artery catheter thermodilution remains invasive. Arterial pressure-based cardiac output (APCO) devices are widely used but still require arterial catheterization. We developed and validated a deep learning (DL) model that simultaneously estimates stroke volume (SV), systolic blood pressure (SBP), and diastolic blood pressure (DBP) using electrocardiogram (ECG) and photoplethysmogram (PPG). Methods: We retrospectively analyzed 881 surgical cases at Seoul National University Hospital (Aug 2016 - Dec 2020) with simultaneous ECG, PPG, arterial blood pressure waveform (ABP), SV measured by the APCO devices, and demographics. After signal-quality rules and arterial-line plausibility filters, 20-s ECG/PPG segments were paired SV to form samples. A DL model using ECG, PPG, the first and second derivatives of PPG, demographic variables, and ECG-derived features simultaneously estimated SV, SBP, and DBP. Model performance was evaluated in a temporal hold-out cohort using error metrics, Bland-Altman analysis, and 10-min interval trend analysis. SBP and DBP performance was assessed against ISO 81060-3:2022 criteria. Results: The test set comprised 128 cases (31,637 segments). Our DL model achieved a mean absolute error of 10.761 mL/beat and percentage limits of agreement ranging from -26.905% to 29.563%. SBP and DBP showed mean errors of 0.661 and 1.439 mmHg, with standard deviations of 9.716 and 6.684 mmHg, respectively, meeting the ISO 81060-3:2022 criteria. Conclusion: A DL model using ECG/PPG and demographics can estimate SV with clinically useful performance while simultaneously predicting SBP/DBP, potentially expanding continuous hemodynamic monitoring to non-arterial-line cases.

Indexed as

cardiac outputdeep learninghemodynamic monitoringmulti-task learningnon-invasiveperioperative monitoringstroke volume

Identifiers

PMID42620791
PMCPMC13487053

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.