ArticleJournal of ultrasound2026
Robotic breast ultrasound with knowledge-guided path planning and vision feedback.
Article in Journal of ultrasound, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
aimsStandardizing robotic breast ultrasound remains challenging in practice, particularly during near-lesion approach, where small nonlinearities can degrade imaging consistency and needle guidance.
methodsThis study uses publicly available datasets to derive skill-informed motion primitives for an ontology-guided path-planning framework and to define a representative breast ultrasound workspace with lesion-oriented linear trajectories. BUSI-derived lesion information is used to generate image-informed scan paths in the imaging plane, while JIGSAWS kinematic sequences are used to initialize motion primitives and neuro-fuzzy inverse-kinematics rules. The proposed robotic ultrasound scan controller maps Cartesian targets to joint commands, and its parameters are subsequently refined using an ant colony optimization for continuous domains (ACOR) strategy. Performance is evaluated in terms of joint-angle error, forward-kinematics path tracking, motion smoothness measured by mean absolute jerk, and needle-heading alignment relative to the planned trajectory.
resultsAmong the untuned variants, the controller initialized by data-driven clustering showed the strongest generalization across the evaluation workspace. ACOR-based refinement further reduced path-tracking error and markedly improved motion smoothness. Orientation alignment also improved relative to the baseline, although performance remained variable across test segments and the predefined success threshold was not achieved in all cases.
conclusionThe proposed knowledge-driven robotic ultrasound framework integrates ontology-guided linear path planning, neuro-fuzzy inverse kinematics, and metaheuristic parameter refinement to achieve accurate and smoother tracking in representative breast-imaging tasks. In the present proof-of-concept study, the image-based component is used primarily for lesion-informed trajectory generation and evaluation rather than full real-time visual servoing. These findings support the feasibility of standardized robotic ultrasound workflows and motivate future integration of explicit orientation costs, force regulation, and real-time image feedback.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.