Evidence map›Paper›PMID 42618727›Full record

Observational studyCanadian journal of anaesthesia = Journal canadien d'anesthesie2026

Accuracy of Bispectral Index™ monitoring in an alternative nasal position in pediatric patients under general anesthesia: a prospective observational study.

Taniga Kiatchai, Pakjira Sombatthaveekul, Niracha Wongchompoo, Pichaya Waitayawinyu, Sujin Suwanna, Jirapat Aiamsophon, Naiyana Aroonpruksakul, Nophanan Chaikittisilpa

Abstract readObservational StudyComparative Study
In one paragraph

Observational study in Canadian journal of anaesthesia = Journal canadien d'anesthesie, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Taniga KiatchaiDepartment of Anesthesiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand.
Pakjira SombatthaveekulDepartment of Anesthesiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand.
Niracha WongchompooDepartment of Anesthesiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand.
Pichaya WaitayawinyuDepartment of Anesthesiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand.
Sujin SuwannaDepartment of Physics, Faculty of Science, Mahidol University, Bangkok, Thailand.
Jirapat AiamsophonSiriraj Informatics and Data Innovation Center, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand.
Naiyana AroonpruksakulDepartment of Anesthesiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand.
Nophanan ChaikittisilpaDepartment of Anesthesiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand. nophanan.chi@mahidol.edu.ORCID http://orcid.org/0000-0002-4210-8066

Funding

Faculty of Medicine Siriraj Hospital, Mahidol University R016732005
6 · The paper itself

Abstract

purposeThe standard frontal Bispectral Index™ (BIS™) monitoring during anesthesia is clinically validated; nevertheless, alternative sensor positions may be necessary when the forehead is inaccessible. We aimed to evaluate the accuracy of BIS monitoring obtained from the nasal region compared with conventional frontal placement in pediatric patients under general anesthesia.

methodsWe included 40 children (aged 4-12 yr) undergoing general anesthesia with sevoflurane in a prospective observational study. We placed pediatric BIS sensors on the forehead and over the nasal bridge and the ipsilateral temporal region. We assessed the agreement between nasal and frontal BIS values. We performed subgroup analyses during different anesthetic phases, electromyography (EMG) activity, and age group. We then compared the power spectral density between nasal and frontal placements.

resultsWe analyzed 5,049 artifact-free paired BIS measurements. The mean (standard deviation) difference between nasal and frontal BIS values was 1.0 (4.5) (95% limits of agreement, -8 to 10), with a good correlation (concordance correlation coefficient, 0.88). The marginal incidence of BIS values exceeding the ±10-unit acceptable threshold was 3.9% (95% confidence interval [CI], 2.1% to 5.8%), with a higher marginal incidence exceeding acceptable limits during emergence (6.6%; 95% CI, 1.3% to 11.8%) and in the high-EMG group (8%; 95% CI, 1% to 15%), and was similar across age groups. Spectral characteristics were comparable, with lower total power at the nasal position.

conclusionsBispectral Index values obtained from the nasal region in pediatric patients agreed within ±10 units of the values from conventional frontal placement. Scalp flap dissection or contamination may alter impedance; thus, BIS should be interpreted cautiously with the density spectral array, ensuring stable impedance for reliable signals.

Indexed as

Anesthesia, GeneralConsciousness MonitorsMonitoring, IntraoperativeAnesthetics, InhalationChildChild, PreschoolElectroencephalographyElectromyographyFemaleForeheadHumansMaleMethyl EthersNosePediatric AnesthesiaProspective StudiesAnesthetics, InhalationMethyl EthersSevofluraneBispectral Index™electroencephalographygeneral anesthesiaintraoperative monitoringneurophysiologic monitoringpediatric anesthesia

Identifiers

PMID42618727
PMCPMC13534209

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.