First performance test of a dual wide-coverage CT system.
Article in European radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study presents a comprehensive performance test of a dual-source wide-coverage CT system, which integrates two 16-cm detectors and two corresponding X-ray tubes on a single gantry. The architecture of the CT system and a dedicated cross-scatter correction algorithm are described, the latter of which is developed for this particular dual wide-coverage geometry and combines physical modeling with empirical calibration. The implemented correction was demonstrated to be effective in reducing cross-scatter artifacts, with preserved spatial resolution (difference < 0.5% at 10% MTF) and low-contrast detectability (3 mm at 0.3% contrast, at a volume CT dose index of 47.6 mGy and a slice thickness of 1.0 mm) after correction. Temporal resolution was assessed using an ECG-signal-driven dynamic phantom, tested with the dual wide-coverage acquisition mode. It provided motion-artifact-free images under simulated sinus rhythm at 100 bpm and arrhythmic conditions varying between 75 and 100 bpm. Clinical performance was further illustrated in a patient with a mean heart rate of 197 bpm, in whom CCTA acquired with this mode showed clear and sharp coronary arteries with minimal motion artifact at a radiation dose of 1.48 mSv. The dual wide-coverage CT system successfully integrates 16-cm wide z-axis coverage with high temporal resolution of the dual-source system, demonstrating potential for advanced dynamic cardiac imaging. KEY POINTS: Question Current CT systems require a compromise between wide z-axis coverage and high temporal resolution, limiting optimal performance in patients with high or irregular heart rates. Findings A novel dual wide-coverage CT system achieved high temporal resolution and motion-artifact-free images across high and irregular heart rates, with effective cross-scatter correction preserving spatial and low-contrast resolution. Clinical relevance The dual wide-coverage CT system enables high-quality coronary CT angiography with high or irregular heart rates, expanding the clinical utility of cardiac CT.