Evidence map›Paper›PMID 42618575›Full record

ArticleScientific reports2026

Comparative outcomes of Forte versus Delta ceramic bearings in total hip arthroplasty using a national database.

Young-Kyun Lee, Danbee Kang, Hyunsoo Kim, Eunjee Kang, Juhee Cho, Jung-Wee Park

Abstract readComparative Study
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Young-Kyun LeeDepartment of Orthopaedic Surgery, Seoul National University Bundang Hospital, 166 Gumi-ro, Bundang-gu, Seongnam, 463-707, South Korea.
Danbee KangDepartment of Clinical Research Design and Evaluation, SAIHST, Sungkyunkwan University, 115 Irwon-Ro, Gangnam-gu, Seoul, 06355, South Korea.
Hyunsoo KimCenter for Clinical Epidemiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea.
Eunjee KangCenter for Clinical Epidemiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea.
Juhee ChoDepartment of Clinical Research Design and Evaluation, SAIHST, Sungkyunkwan University, 115 Irwon-Ro, Gangnam-gu, Seoul, 06355, South Korea. jcho@skku.edu.
Jung-Wee ParkDepartment of Orthopaedic Surgery, Seoul National University Bundang Hospital, 166 Gumi-ro, Bundang-gu, Seongnam, 463-707, South Korea. jwepark@gmail.com.

Funding

Ministry of Food and Drug Safety 21173MFDS244
6 · The paper itself

Abstract

Despite their widespread use, relatively little is known about the comparative survivorship of Forte-on-Forte (FoF) versus Delta-on-Delta (DoD) ceramic bearings with respect to risk of revision after total hip arthroplasty (THA). The purpose of this study was to evaluate (1) the national trends of FoF and DoD in THA, and (2) survivorship of THA with FoF versus DoD, using nationwide data from the NHIS (national health insurance service). We identified 124,556 adult patients who underwent primary THA between 2003 and 2019. Among them, 75,475 patients who underwent ceramic-on-ceramic THA with either Forte-on-Forte or Delta-on-Delta bearings were ultimately included after applying the exclusion criteria. Dislocation, periprosthetic joint infection (PJI), and periprosthetic fracture within 30 days, 90 days, and 1 year were compared between the Forte and Delta groups. Survivorship was evaluated using stem revision, cup revision, and any revision as endpoints. Among a total of 75,475 THA with CoC, DoD was utilized in 43,552 patients (57.7%) and FoF in 31,923 patients (42.3%). Utilization of DoD increased with a decrease of FoF since 2007. Forte bearings were associated with a higher risk of dislocation within 30 days compared with Delta bearings (aHR = 1.43; 95% CI = 1.21-1.69), and this association persisted at 1 year (aHR = 1.46; 95% CI = 1.34-1.60). The 10-year survival rates in the Delta group were higher for cup revision (98.6%, 95% CI = 98.4-98.8) and any revision (96.5%, 95% CI = 96.2-96.7) than those in the Forte group. Delta-on-Delta ceramic bearings were associated with lower risks of dislocation and revision compared with Forte-on-Forte bearings in this nationwide claims-based cohort.

Indexed as

Arthroplasty, Replacement, HipCeramicsHip ProsthesisAdultAgedDatabases, FactualFemaleHumansMaleMiddle AgedProsthesis DesignProsthesis FailureReoperationTreatment OutcomeCeramic bearingsComparison studyComplicationNational registrySurvivorshipTotal hip arthroplasty

Identifiers

PMID42618575
PMCPMC13490454

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.