Evidence map›Paper›PMID 42616767›Full record

ArticlePloS one2026

Adaptive and resilient protection coordination in smart microgrids enabled by a directional fault current limiter.

I M Shindy, Aymen Flah, Mostafa G Rabea, Said Elmasry, Adel A El Samhay, M M R Ahmed, A M Hamada

Abstract read
In one paragraph

Article in PloS one, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

I M ShindyElectrical Power and Machine Department, Faculty of Engineering, Capital University, Cairo, Egypt.
Aymen FlahApplied Science Research Center, Applied Science Private University, Amman, Jordan.
Mostafa G RabeaElectrical Power and Machine Department, Faculty of Engineering, Capital University, Cairo, Egypt.
Said ElmasryElectrical Power and Machine Department, Faculty of Engineering, Capital University, Cairo, Egypt.
Adel A El SamhayElectrical Power and Machine Department, Faculty of Engineering, Capital University, Cairo, Egypt.
M M R AhmedDepartment of Electrical Technology, Faculty of Technology and Education, Capital University, Egypt.ORCID https://orcid.org/0000-0002-2066-4256
A M HamadaRailway and Modern Transportation Technology Program, Faculty of Industrial and Energy Technology, Borg Al Arab Technological University (BATU), New Borg El Arab Alexandria, Egypt.ORCID https://orcid.org/0000-0001-6242-7948

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Power systems, particularly distribution networks, are currently facing increasing challenges due to rising energy demand and the growing complexity of modern grids. The integration of Distributed Generators (DGs) within Microgrids (MGs) introduces additional fault current contributions, which significantly modify short-circuit levels. This change can result in miscoordination problems in existing Overcurrent Relay (OCR)-based protection systems, including both maloperation and delayed tripping. In addition, the increased fault current contribution from MGs may exceed the design limits of equipment such as circuit breakers (CBs), exposing them to higher electrical stress and increasing the risk of failure to operate properly. Consequently, these issues collectively degrade the overall reliability and security of the power system. To overcome these challenges, installing a Directional Fault Current Limiter (DFCL) between the microgrid and the upstream network is considered an effective mitigation approach. The DFCL helps in controlling fault current levels and improving protection coordination. However, determining the optimal impedance setting of the DFCL is a complex task, as it must simultaneously ensure proper coordination among OCRs and reduce short-circuit levels to enhance system reliability. In this context, this paper proposes an analytical methodology for determining the optimal DFCL impedance based on Thevenin equivalent impedance analysis. The proposed approach provides a straightforward impedance sizing procedure that restores overcurrent relay coordination following distributed generation integration while maintaining system reliability. Unlike optimization-based methods, the proposed analytical approach determines the required DFCL impedance directly from the equivalent Thevenin impedance without iterative computation, making it computationally efficient and suitable for real-time engineering application The methodology is validated under different operating scenarios involving synchronous generators, wind turbine generators, and photovoltaic systems. The results demonstrate that the proposed approach effectively restores relay coordination, limits excessive fault currents, and enhances the reliability of microgrid protection without requiring adaptive protection schemes or additional relay installation.

Indexed as

Electric Power SuppliesAlgorithmsEquipment Design

Identifiers

PMID42616767
PMCPMC13489461

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.