Evidence map›Paper›PMID 42613830›Full record

ArticleMedical physics2026

Efficient and rapid generation of high-quality CT images from CBCT using a flow matching model.

Zhibin Li, Li Chen, Guanghui Gan, Jian Guo, Songbing Qin, Long Chen

Abstract read
In one paragraph

Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Zhibin LiDepartment of Radiation Oncology, The First Affiliated Hospital of Soochow University, Suzhou, China.
Li ChenDepartment of Radiation Oncology, The Second Affiliated Hospital of Soochow University, Suzhou, China.
Guanghui GanDepartment of Radiation Oncology, The First Affiliated Hospital of Soochow University, Suzhou, China.
Jian GuoDepartment of Radiation Oncology, The First Affiliated Hospital of Soochow University, Suzhou, China.
Songbing QinDepartment of Radiation Oncology, The First Affiliated Hospital of Soochow University, Suzhou, China.
Long ChenDepartment of Radiation Oncology, The First Affiliated Hospital of Soochow University, Suzhou, China.

Funding

Jiangsu Provincial Medical Key Discipline ZDXK202235National Natural Science Foundation of China 82473249Noncommunicable Chronic Diseases-National Science and Technology Major Project 2024ZD0525900
6 · The paper itself

Abstract

backgroundGenerating high-quality CT images from cone-beam computed tomography (CBCT) is critical for clinical applications such as online adaptive radiotherapy (ART). Although deep learning methods, including diffusion models, have shown remarkable advances, persistent challenges remain in terms of image quality and computational efficiency. PURPOSE: This study aims to leverage the flow matching model for CBCT-to-CT translation, enabling the rapid and efficient synthesis of high-quality CT images for clinical application.

methodsOur proposed method is built upon the flow matching model, a powerful multi-step generative framework that is designed to construct a continuous trajectory that transforms data from a prior distribution to a complex target distribution. A cohort of 135 abdominal-pelvic CT scans was used for model training (95 cases), validation (15 cases), and testing (25 cases). To ensure accurate evaluation, a dataset of rigorously paired CBCT-CT images was generated by simulating the CBCT imaging process. A comprehensive assessment of the model's performance was conducted with respect to structural consistency, detail fidelity, image blurring, and texture realism. The proposed method was benchmarked against the state-of-the-art probabilistic diffusion model.

resultsAs the number of sampling steps increases, the metrics reflecting image sharpness exhibit a consistent upward trend, indicating progressive improvement in clarity. An optimal balance among textual realism, detail fidelity, and computational efficiency was achieved within the 20-50 step range. At the 20 sampling steps, the proposed model can generate a 100-slice CT volume within 20 s, with a mean absolute error (MAE) of 12.25, a structure similarity index measure (SSIM) of 0.977, and a peak signal-to-noise ratio (PSNR) of 42.03. Compared to the conventional diffusion model, the proposed method delivers superior performance with fewer sampling steps, demonstrating its potential for efficient generation of high-quality medical images.

conclusionsThe proposed flow matching model enables efficient and rapid generation of high-quality synthetic CT images from CBCT, substantially outperforming existing diffusion models and demonstrating strong potential for time-sensitive clinical applications such as online ART.

Indexed as

Cone-Beam Computed TomographyImage Processing, Computer-AssistedHumansQuality ControlTime Factorsdiffusion modelflow matchingsynthetic CT

Identifiers

PMID42613830
PMCPMC13486935

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.