Evidence map›Paper›PMID 42613795›Full record

ArticleJournal of applied clinical medical physics2026

Deep learning auto-contouring of target and organs-at-risk on post-catheter implant CT images for prostate HDR brachytherapy.

Eric M Wallat, Joseph B Schulz, John M Floberg, Gregory Cooley, Bryan P Bednarz, Jordan M Slagowski

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Eric M WallatDepartment of Radiation Medicine, University of Wisconsin-Madison, Madison, Wisconsin, USA.
Joseph B SchulzDepartment of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.
John M FlobergDepartment of Radiation Medicine, University of Wisconsin-Madison, Madison, Wisconsin, USA.
Gregory CooleyDepartment of Radiation Medicine, University of Wisconsin-Madison, Madison, Wisconsin, USA.
Bryan P BednarzDepartment of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.
Jordan M SlagowskiDepartment of Radiation Medicine, University of Wisconsin-Madison, Madison, Wisconsin, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAccurate delineation of the prostate and surrounding organs-at-risk (OARs) is essential for HDR prostate brachytherapy. Manual contouring on post-catheter CT images is time-consuming and prone to variability due to artifacts and anatomical deformation from the implanted brachytherapy catheters. PURPOSE: To develop and validate a 3D deep learning autosegmentation model for prostate and OAR contouring on post-catheter CT images for prostate brachytherapy planning.

methodsA self-configuring U-Net architecture (nnU-Net) was trained on 206 HDR prostate brachytherapy cases and tested on an additional 36 patients. Structures included prostate PTV, bladder, rectum, and urethra identified from a Foley catheter. Performance was evaluated against a commercially available model using geometric (Dice coefficient (DSC), Hausdorff distance (HD95%), average surface distance (ASD)) and dosimetric metrics (PTV V100%, bladder and rectum D1cc, urethra D0.1cc). Statistical significance was assessed using paired Wilcoxon signed-rank tests.

resultsNnU-Net achieved superior geometric accuracy versus the commercial model for all structures within slices containing the prostate. For prostate PTV, nnU-Net yielded DSC = 0.91 +/- 0.04, HD95% = 3.62 +/- 2.23 mm, and ASD = 1.25 +/- 0.66 mm, compared to DSC = 0.78 +/- 0.07, HD95% = 9.52 +/- 4.73 mm, and ASD = 2.97 +/- 0.90 mm for the commercial model. Urethra segmentation was only provided by nnU-Net (DSC = 0.84 +/- 0.09). Dosimetric differences for nnU-Net were clinically negligible: ΔPTV V100% = -0.25 +/-2.30%, bladder ΔD1cc = 0.13 +/- 0.75 Gy, rectum ΔD1cc = 0.34 +/- 0.74 Gy, and urethra ΔD0.1cc = -0.03 +/- 0.16 Gy. Differences in PTV V100% were not significant for nnU-Net (p = 0.91) but significant for the commercial model (p < 0.001).

conclusionsA brachytherapy-specific nnU-Net model enables accurate autosegmentation of prostate and OARs on post-catheter CT images, outperforming an EBRT-trained commercial solution. Minimal dosimetric differences support clinical feasibility and potential workflow improvements in HDR prostate brachytherapy.

Indexed as

BrachytherapyDeep LearningImage Processing, Computer-AssistedOrgans at RiskProstatic NeoplasmsRadiotherapy Planning, Computer-AssistedTomography, X-Ray ComputedHumansMaleRadiotherapy DosageRadiotherapy, Intensity-Modulatedbrachytherapydeep learningprostate cancersegmentation

Identifiers

PMID42613795
PMCPMC13486957

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.