Resolution-noise characteristics of common FDK filter kernels: A practical reference for preclinical cone-beam micro-CT.

Falk L Wiegmann, Nancy L Ford

Abstract read
In one paragraph

Article in PloS one, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Falk L WiegmannDepartment of Physics and Astronomy, The University of British Columbia, Vancouver, British Columbia, Canada.ORCID https://orcid.org/0009-0009-2225-3571
Nancy L FordDepartment of Physics and Astronomy, The University of British Columbia, Vancouver, British Columbia, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The ramp filter kernel and cutoff frequency are fundamental parameters of the Feldkamp-Davis-Kress (FDK) algorithm that determine the resolution and noise characteristics of the reconstructed image. Despite their importance, the filter configuration is frequently unreported in preclinical micro-CT studies. We reconstruct identical data from a GE eXplore CT 120 scanner using four filter kernels (ramp, Shepp-Logan, cosine, Hamming) at four cutoff frequencies (1.0, 0.8, 0.6, and 0.379× Nyquist, matched to the detector-to-voxel size ratio) and evaluate each of the sixteen configurations using the modulation transfer function (MTF), noise power spectrum (NPS), and non-prewhitening detectability index (NPW d'). Qualitative assessment is performed on a mouse lung specimen. Across the sixteen configurations, MTF10 ranges from 1.74 to 3.22 lp/mm, integrated NPS from 75 670 to 13 259 HU2, and the Rose criterion crossing diameter from 2.03 to 0.90 mm at ΔC=500 HU and from 6.89 to 3.56 mm at 100 HU. This note presents the data as a concise, primarily comparative visual and quantitative reference for FDK filter selection in preclinical cone-beam CT.

Indexed as

AlgorithmsCone-Beam Computed TomographyImage Processing, Computer-AssistedX-Ray MicrotomographyAnimalsLungMiceSignal-To-Noise Ratio

Identifiers

PMID42611858
PMCPMC13484966

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.