Evidence map›Paper›PMID 42611185›Full record

ArticleNeuroradiology2026

First-in-human use of SmartGUIDE

Jeremy Hofmeister, Gianmarco Bernava, Andrea Rosi, Olivier Brina, Philippe Reymond, Hasan Yilmaz, Michel Muster, Guillaume Petitpierre, Marc Boers, Priya Gaiha and 2 more

Abstract read
PubMed Publisher
In one paragraph

Article in Neuroradiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Jeremy HofmeisterDepartment of Diagnostic & Interventional Neuroradiology, University Hospital of Geneva, Geneva, Switzerland. jeremy.hofmeister@hug.ch.
Gianmarco BernavaDepartment of Diagnostic & Interventional Neuroradiology, University Hospital of Geneva, Geneva, Switzerland.
Andrea RosiDepartment of Diagnostic & Interventional Neuroradiology, University Hospital of Geneva, Geneva, Switzerland.
Olivier BrinaDepartment of Diagnostic & Interventional Neuroradiology, University Hospital of Geneva, Geneva, Switzerland.
Philippe ReymondDepartment of Diagnostic & Interventional Neuroradiology, University Hospital of Geneva, Geneva, Switzerland.
Hasan YilmazDepartment of Diagnostic & Interventional Neuroradiology, University Hospital of Geneva, Geneva, Switzerland.
Michel MusterDepartment of Diagnostic & Interventional Neuroradiology, University Hospital of Geneva, Geneva, Switzerland.
Guillaume PetitpierreArtiria Medical, Geneva, Switzerland.
Marc BoersArtiria Medical, Geneva, Switzerland.
Priya GaihaArtiria Medical, Geneva, Switzerland.
Karl-Olof LovbladDepartment of Diagnostic & Interventional Neuroradiology, University Hospital of Geneva, Geneva, Switzerland.
Paolo MachiDepartment of Diagnostic & Interventional Neuroradiology, University Hospital of Geneva, Geneva, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo report the first-in-human, prospective clinical evaluation of a steerable 0.014″ microguidewire SmartGUIDE™ (Artiria Medical, Switzerland) for endovascular treatment of intracranial aneurysms, assessing technical feasibility, safety, and operator-reported usability.

methodsAdult patients undergoing elective treatment of unruptured intracranial aneurysms were prospectively enrolled between August 2023 and July 2024 at a single center. All procedures were performed by a senior neurointerventionalist. The primary endpoint was the device technical success, defined as successful SmartGUIDE™ navigation to a predefined anatomical target. Successful microcatheterization over the wire was a clinically meaningful secondary endpoint, together with safety, device-related adverse events, navigation time, and operator-reported usability (5-point Likert scale). Patient-specific Flow Twin

resultsFive patients were included. SmartGUIDE™ successfully reached the predefined target in all procedures (5/5). Microcatheterization was achieved in four cases (4/5). Median SmartGUIDE navigation time was 7 min (IQR 4-10). No wire-related complications or device malfunctions were observed. Operators reported high device usability, with median Likert scores of 4-5/5 across all parameters. At 1-year follow-up, all aneurysms demonstrated complete and stable occlusion without neurological morbidity.

conclusionThis first-in-human prospective series supports the feasibility and safety of the SmartGUIDE™ steerable 0.014″ microguidewire for the treatment of intracranial aneurysms. The study reports reliable navigation to the target without device-related malfunction or complication, favorable operator-reported usability, and highlights the value of incorporating patient-specific flow-models for pre-procedural training. Comparative studies are required to establish efficiency advantage over conventional microguidewires.

Indexed as

CerebralEndovascularInnovationMedical devicePre-therapeutic training

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.