Evidence map›Paper›PMID 42609606›Full record

ArticleClinical ophthalmology (Auckland, N.Z.)2026

Clinical Performance of an Isofocal Toric Intraocular Lens with Double C-Loop Haptics: A Multicenter Retrospective Study.

Sheraz Daya, Takayuki Akahoshi, Camille Bosc, Alessandra Di Maria, Marcela Espinosa Lagana, Noemi Sasso, Alessandro Gaeta

Abstract read
In one paragraph

Article in Clinical ophthalmology (Auckland, N.Z.), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sheraz DayaCentre for Sight, East Grinstead, UK.ORCID 0000-0002-0025-0646
Takayuki AkahoshiNihonbashi Cataract-Clinic, Tokyo, Japan.
Camille BoscClinique Jules Verne, Nantes, France.
Alessandra Di MariaIRCCS Humanitas Research Hospital, Milan, Italy.ORCID 0000-0002-4889-6315
Marcela Espinosa LaganaCentre for Sight, East Grinstead, UK.
Noemi SassoIRCCS Humanitas Research Hospital, Milan, Italy.
Alessandro GaetaDepartment of Internal Medicine and Medical Specialties (DIMI), Università Di Genova, Genova, Italy.ORCID 0000-0002-8714-4052

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To evaluate clinical outcomes in eyes with pre-existing astigmatism undergoing cataract surgery or refractive lens exchange with the implantation of an isofocal optic-design toric intraocular lens (IOL) with double C-loop haptics. Method: This multicenter retrospective study comprised 100 eyes (65 patients) implanted with the Isopure Serenity toric IOL (BVI, Inc.) conducted across four sites. Postoperative evaluation at between 2 and 3 months included manifest refraction, monocular uncorrected and distance corrected visual acuity (UDVA and CDVA), monocular uncorrected and distance corrected intermediate visual acuity (UIVA and DCIVA, at 80 and 66 cm), monocular uncorrected and distance corrected near visual acuity (UNVA and DCNVA, at 40 cm), binocular defocus curve and rotational stability. Results: Manifest refraction spherical equivalent and refractive astigmatism were -0.24±0.41D and -0.36±0.36D, respectively. About 79% and 97% of eyes were within ±0.50D and ±1.00D, respectively, and 80% and 96% of eyes were ≤0.50D and ≤1.00D of refractive cylinder, respectively. At distance vision, the mean monocular CDVA was -0.02±0.06 logMAR and 92.93% of eyes showed a CDVA of ≥20/20. At intermediate vision, the mean monocular DCIVA values were 0.10±0.07 and 0.17±0.10 logMAR at 80 cm and 66 cm, respectively; and 96.92% and 88.33% of eyes showed a DCIVA of ≥20/32 at 80 cm and 66 cm, respectively. At near vision, the mean monocular DCNVA was 0.31±0.08 logMAR and 75.44% of eyes showed a DCNVA of ≥20/40. The binocular depth of focus range was approximately 1.50D. The mean absolute IOL rotation was 2.73±2.58 degrees with all eyes having a rotation of <10 degrees. Conclusions: Eyes with pre-existing astigmatism implanted with the Isopure Serenity toric IOL showed good distance visual acuity and functional intermediate vision, with high refractive accuracy and good rotational stability following cataract and refractive lens exchange surgery.

Indexed as

astigmatismcataractdouble C-loopintraocular lensisofocaltoric

Identifiers

PMID42609606
PMCPMC13479079

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.