Evidence map›Paper›PMID 42609042›Full record

ArticleJournal of orthopaedic research : official publication of the Orthopaedic Research Society2026

Fractures Around Collared and Collarless Hip Stems Initiate in High Strain Regions: A Combined Cadaveric Experiment and Finite Element Analysis.

Ryan T Helbock, Clarisse Zigan, Andrew Hughes, Joseph D Lipman, Timothy M Wright, Peter K Sculco, Elizabeth B Gausden, Sony Manandhar, Ghislain Maquer, Jeff Bischoff and 1 more

Abstract read
In one paragraph

Article in Journal of orthopaedic research : official publication of the Orthopaedic Research Society, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Ryan T HelbockDepartment of Biomechanics, Hospital for Special Surgery, New York City, New York, USA.ORCID https://orcid.org/0009-0003-0204-0284
Clarisse ZiganDepartment of Biomechanics, Hospital for Special Surgery, New York City, New York, USA.ORCID https://orcid.org/0009-0000-6964-6465
Andrew HughesAdult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York City, New York, USA.ORCID https://orcid.org/0000-0003-2335-199X
Joseph D LipmanDepartment of Biomechanics, Hospital for Special Surgery, New York City, New York, USA.ORCID https://orcid.org/0000-0002-6576-8219
Timothy M WrightDepartment of Biomechanics, Hospital for Special Surgery, New York City, New York, USA.ORCID https://orcid.org/0000-0001-7139-1908
Peter K SculcoAdult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York City, New York, USA.ORCID https://orcid.org/0000-0001-7050-5571
Elizabeth B GausdenAdult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York City, New York, USA.ORCID https://orcid.org/0000-0001-8596-3292
Sony ManandharZimmer Biomet, Warsaw, Indiana, USA.ORCID https://orcid.org/0009-0006-8302-7269
Ghislain MaquerZimmer Biomet, Warsaw, Indiana, USA.ORCID https://orcid.org/0009-0007-8255-9738
Jeff BischoffZimmer Biomet, Warsaw, Indiana, USA.ORCID https://orcid.org/0000-0001-5330-1227
Fernando J Quevedo GonzalezDepartment of Biomechanics, Hospital for Special Surgery, New York City, New York, USA.ORCID https://orcid.org/0000-0001-6521-8754

Funding

Zimmer Biomet 10.13039/100012630
6 · The paper itself

Abstract

Periprosthetic femoral fracture (PFF) is a common early complication after primary total hip arthroplasty. Collared stems reduce but do not eliminate the incidence of PFF, and exhibit variable biomechanical effectiveness, emphasizing our limited understanding of the local bone-implant interaction mechanics. Our goal was to elucidate the relationship between the local strains at the bone-implant interface and the experimental fracture patterns and loads for collared and collarless stems. Six pairs of women cadaveric femurs implanted with a collarless or collared stem were loaded to failure under simulated stumbling to determine the location of PFF and the load to fracture, which we related to the collar-calcar separation. Corresponding specimen-specific FE models were developed to determine the strain at the bone-implant interface and to predict the fracture onset load and location of fracture, which we related to the experimental location of PFF and the load-to-fracture. Load to fracture was greater for collared stems and was inversely correlated with the collar-calcar separation at the time of implantation (r = -0.80, p = 0.055). Fractures occurred in areas of high strain. The experimental fracture location coincided with the first yielding cortical element in five cases. The load at which the first cortical element yielded (i.e., onset of fracture was moderately correlated with the experimental fracture load (R

Indexed as

Arthroplasty, Replacement, HipFemoral FracturesHip ProsthesisPeriprosthetic FracturesAgedAged, 80 and overBiomechanical PhenomenaCadaverFemaleFinite Element AnalysisHumansMiddle AgedProsthesis DesignStress, Mechanicalbone–implant interfacecollared femoral stemsfinite element modelingfracture initiationperiprosthetic femoral fracturestrain‐based failure prediction

Identifiers

PMID42609042
PMCPMC13482135

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.