ArticleBone & joint research2026
In vivo quantification of polyethylene wear in total ankle arthroplasty : a longitudinal study using weightbearing CT.
Article in Bone & joint research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Aims: In vivo assessment of polyethylene (PE) wear in total ankle arthroplasty (TAA) relies on approximation using 2D metal interspace height (2D-MIH) loss on weightbearing radiographs. Weightbearing CT (WBCT), combined with distance mapping, may improve quantification of PE wear over time using 3D metal interspace volume (3D-MIV) loss. This study aimed to assess 3D-MIV with successive WBCT scans. We hypothesized that WBCT based 3D-MIV would enable longitudinal quantification of PE wear and identify predictors. Methods: This retrospective study included 29 ankles from 28 TAA patients (16 men, mean age 57.9 years (SD 10.5), BMI 26.3 kg/m² (SD 4.1)) who had WBCT scans at minimum two-year intervals. Patients aged below 18 years, and those with trauma or surgical procedures affecting ankle alignment between scans, were excluded. Demographic data, implant types, and clinical outcomes were extracted. 3D-MIV was measured after segmentation of individual bones and prosthetic components. Annualized approximated wear rates were calculated. Correlations and multivariate regression analyses were used to identify predictors. Results: Mean follow-up between scans was 58.7 months (SD 17.9). Mean 3D-MIV decreased from 3.92 mL (SD 1.17) initially to 3.86 mL (SD 1.11) (p = 0.015). Yearly 3D-MIV loss was -11.34 mm³/year (SD 19.62). Correlations existed between 3D-MIV loss and coronal plane rotation (ρ = -0.58, p < 0.001), mediolateral translation (ρ = -0.52, p = 0.004, superoinferior translation (ρ = 0.56, p = 0.002) and BMI ≥ 27 kg/m² (p = 0.037). Multivariate regression identified coronal plane alignment ( Conclusion: Using a WBCT-based approach, this study enabled longitudinal in vivo quantification of PE wear in TAA. Wear rates (~11.3 mm³/year) aligned with prior estimates, and the method correctly identified anticipated predictors of increased wear.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.