Evidence map›Paper›PMID 42605022›Full record

ArticleJournal of applied clinical medical physics2026

Flexible intervention workflow for MRI guided robotic prostate seed brachytherapy.

Philipp Aumueller, Mirjam L Dannert, Martin Polednik, Frank A Giordano, Jens Fleckenstein, Sven Clausen

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Philipp AumuellerDepartment of Radiation Oncology, University Medical Centre Mannheim, University Heidelberg, Mannheim, Germany.
Mirjam L DannertDepartment of Radiation Oncology, University Medical Centre Mannheim, University Heidelberg, Mannheim, Germany.
Martin PolednikDepartment of Radiation Oncology, University Medical Centre Mannheim, University Heidelberg, Mannheim, Germany.
Frank A GiordanoDepartment of Radiation Oncology, University Medical Centre Mannheim, University Heidelberg, Mannheim, Germany.
Jens FleckensteinDepartment of Radiation Oncology, University Medical Centre Mannheim, University Heidelberg, Mannheim, Germany.
Sven ClausenDepartment of Radiation Oncology, University Medical Centre Mannheim, University Heidelberg, Mannheim, Germany.

Funding

German Federal Ministry of Education and Research (BMBF) within the Framework "Forschungscampus: public-private partnership for Innovations" 13GW0092D
6 · The paper itself

Abstract

backgroundLow-dose-rate prostate seed brachytherapy (BT) is an established guideline-conformal treatment option for low-risk prostate cancer. Precise seed placement is essential for achieving adequate dose coverage while minimizing exposure of surrounding healthy tissue. MRI guidance offers superior soft-tissue contrast for target visualization, but technical challenges remain for accurate transrectal seed implantation under in-bore conditions. PURPOSE: The Remote Control Manipulator (RCM) is an MRI-compatible robotic guidance system originally designed for in-bore transrectal targeted prostate biopsies. This work investigates its feasibility for MRI-guided transrectal targeted focal prostate seed BT. We demonstrate the intervention workflow and quantify seed placement accuracy in a preclinical phantom experiment.

methodsThe proposed intervention workflow defines the setup steps, interaction of the treatment planning system (TPS) with the robot's navigation software, MR-imaging as well as seed- and needle-guide registration. We performed and analyzed the total workflow in an anthropomorphic pelvis phantom. Seed positions corresponding to the initial treatment plan, the expected positions after needle-guide alignment, and the final released seed positions were assessed in detail. Their geometric displacement was decomposed into contributions from robotic alignment, seed release, and registration uncertainty. Dosimetric consequences were evaluated using the target's V

resultsRobotic alignment produced a mean expected seed displacement of 0.6 ± 0.2 mm. Total deviation from planned to released seed positions was 2.6 ± 0.9 mm, with 0.7 ± 0.4 mm along-trajectory displacement. MRI-only seed registration differed from CT-verified reconstruction by 2.8 ± 1.4 mm. After two released needles, V

conclusionsThe workflow was successfully executed and demonstrated sub-millimeter robotic targeting precision. Seed displacement during release and limited MRI-only seed localization remain dominant sources of error impacting dose coverage. Active needle guidance during imaging and improved MRI-only seed reconstruction could enable monitoring the live dose distribution and adaptive trajectory correction.

Indexed as

BrachytherapyMagnetic Resonance ImagingPhantoms, ImagingProstatic NeoplasmsRadiotherapy, Image-GuidedRadiotherapy Planning, Computer-AssistedRoboticsWorkflowHumansMaleOrgans at RiskRadiotherapy DosageRadiotherapy, Intensity-Modulatedbrachytherapyfocal therapyMRIrobotic guidanceseed placement

Identifiers

PMID42605022
PMCPMC13478375

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.