Evidence map›Paper›PMID 42602059›Full record

ArticleFrontiers in bioengineering and biotechnology2026

The size effect on mechanical and permeability properties of porous bone structures fabricated by selective laser melting.

Yongtao Lyu, Hongrui Cao, Peiqi Jing, Yunfei Lan, Sergei Bosiakov, Haytham Elgazzar, Guangyu Li, Yadong Liu

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yongtao LyuDepartment of Spinal Surgery, Central Hospital of Dalian University of Technology, Dalian University of Technology, Dalian, China.
Hongrui CaoSchool of Mechanics and Aerospace Engineering, Dalian University of Technology, Dalian, China.
Peiqi JingSchool of Mechanics and Aerospace Engineering, Dalian University of Technology, Dalian, China.
Yunfei LanDUT-BSU Joint Institute, Dalian University of Technology, Dalian, China.
Sergei BosiakovFaculty of Mechanics and Mathematics, Belarusian State University, Minsk, Belarus.
Haytham ElgazzarThe Advanced Digital Manufacturing Department, Central Metallurgical Research and Development Institute, El-Tebbin, Helwan, Egypt.
Guangyu LiSchool of Materials Science and Engineering, Dalian University of Technology, Dalian, China.
Yadong LiuDepartment of Spinal Surgery, Central Hospital of Dalian University of Technology, Dalian University of Technology, Dalian, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Porous structures are extensively utilized in bone tissue engineering for their lightweight nature, high strength-to-weight ratio, and superior energy absorption capacity. However, achieving optimal scaffold performance through precise dimension control remains a significant design challenge. This study systematically investigates the effect of unit-cell size on the mechanical and fluid transport properties of porous bone structures, aiming to provide guidance for scaffold design. Various porous structures with controlled unit cell sizes were fabricated via Selective Laser Melting (SLM) and evaluated under compressive loading. A complementary finite element (FE) model was developed to simulate mechanical responses and extract equivalent elastic modulus and compressive strength, while computational fluid dynamics (CFD) simulations were conducted on 4 × 4 × 4 arrays to calculate permeability. Results demonstrate that the Gyroid unit cell exhibited the most uniform stress distribution among the three studied architectures (Cube, Octa, Gyroid), and reducing unit cell size effectively mitigated stress concentrations to enhance structural stability. At a constant porosity, the compressive strength of uniform porous structures decreased with increasing unit-cell size, whereas the elastic modulus showed relatively low sensitivity to size variation. Meanwhile, permeability increased markedly with increasing unit-cell size. This study confirms that unit cell size profoundly impacts both the mechanical integrity and permeability of porous bone structures: smaller unit cells are recommended for applications prioritizing high compressive strength, whereas larger unit cells are more favorable for enhanced fluid transport.

Indexed as

Bone scafoldscomputational fluid dynamicsfinite element analysisporous structuresselective laser meltingsize effecttriply periodic minimal surface

Identifiers

PMID42602059
PMCPMC13473008

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.