Comparing the Feasibility of S-Patch vs 24-Hour Holter in Frail Older People With Falls: Randomized Open-Label Crossover Pilot Study.

Barbara Rosario, Vern Hsen Tan, Vivian Cantiller Barrera, Hnin Tun Mon, Clara Yi-En Seah, Colin Yeo

Abstract read
In one paragraph

Article in JMIR rehabilitation and assistive technologies, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Barbara RosarioDepartment of Geriatric Medicine, Changi General Hospital, 2 Simei Street 3, Singapore, 529889, Singapore, 65 84829406.ORCID http://orcid.org/0000-0001-5491-3524
Vern Hsen TanDepartment of Cardiology, Changi General Hospital, Singapore, Singapore.ORCID http://orcid.org/0000-0003-0164-7924
Vivian Cantiller BarreraDepartment of Geriatric Medicine, Changi General Hospital, 2 Simei Street 3, Singapore, 529889, Singapore, 65 84829406.ORCID http://orcid.org/0009-0006-9888-030X
Hnin Tun MonHealth Services Research, Changi General Hospital, Singapore, Singapore.ORCID http://orcid.org/0000-0002-5428-4825
Clara Yi-En SeahDepartment of Emergency Medicine, Changi General Hospital, Singapore, Singapore.ORCID http://orcid.org/0000-0003-2270-0174
Colin YeoDepartment of Cardiology, Changi General Hospital, Singapore, Singapore.ORCID http://orcid.org/0000-0002-1888-2246

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Falls commonly cause injuries in older adults and can present with syncope or presyncope. Typically, frail older adults with cognitive impairment are underrepresented in research and experience difficulty tolerating conventional ECG monitoring devices. S-Patch is a novel, lightweight dual-lead device designed to provide continuous ECG monitoring for up to 72 hours with minimal interference to daily activities. Objective: This study aimed primarily to evaluate the feasibility, tolerability, and adherence of the S-Patch compared with standard 24-hour Holter monitoring in older adults (aged ≥60 years) presenting with unwitnessed falls, syncope, or near-syncope, as assessed by wear duration, completion rates, and patient-reported experience. The secondary objective of this study was to assess device usability and compare arrhythmia detection rates between the devices in a real-world setting. Methods: This prospective, single-center, randomized, open-label, crossover feasibility pilot study was conducted from March 8, 2020, to February 28, 2023. Participants were randomized 1:1 into group A (Holter followed by S-Patch) or group B (S-Patch followed by Holter), enabling up to 4 days of continuous monitoring. Results: Seventy patients were enrolled, of whom 32 (45.7%) had cognitive impairment, and the majority were frail. Group A participants were older (86.9 vs 82.9 years) with higher use of dementia medications (6/35, 17.1% vs 3/35, 8.6%). Frailty was highly prevalent across the cohort, and fear of falling was significantly greater among frail patients (P=.04). Both devices were well tolerated, with no difference in overall device preference, but S-Patch enabled substantially longer monitoring durations compared to Holter. Mean S-Patch wear time exceeded 60 hours and was significantly longer when the device was applied first (68.8 vs 62.9 h; P=.04), suggesting acceptance and adherence. Importantly, tolerability was maintained in frail patients with cognitive impairment. Arrhythmia detection rates were observed as comparable, with both devices identifying one clinically significant arrhythmia, resulting in pacemaker implantation. Conclusions: S-Patch is a feasible, well-tolerated cardiac monitoring device in frail older adults and those with cognitive impairment. Compared with Holter, S-Patch supported longer continuous monitoring without compromising patient acceptability, an important consideration in real-world clinical practice.

Indexed as

arrhythmiafallsfrailtygeriatricsmonitoringsyncope