Evidence map›Paper›PMID 42598565›Full record

ArticleJournal of the Pediatric Orthopaedic Society of North America2026

No Difference Between Intramedullary Kirschner-Wires and Titanium Elastic Nails in Treating Pediatric Femur Fractures: Results From a Randomized Clinical Trial in Dar Es Salaam, Tanzania.

Msami Evarist Ngowi, Billy Haonga, Revocatus Benard Luziba, Bryson Mcharo Ikoshi, Emmanuel Roagthe Lema, Edmund Ndalama Eliezer, Patricia Rodarte, Mayur Urva, Jamieson O'Marr, John Ibrahim and 4 more

Abstract read
In one paragraph

Article in Journal of the Pediatric Orthopaedic Society of North America, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Msami Evarist NgowiMuhimbili Orthopaedic Institute, Muhimbili University of Health and Allied Sciences, Dar es Salaam, Tanzania.
Billy HaongaMuhimbili Orthopaedic Institute, Muhimbili University of Health and Allied Sciences, Dar es Salaam, Tanzania.
Revocatus Benard LuzibaMuhimbili Orthopaedic Institute, Muhimbili University of Health and Allied Sciences, Dar es Salaam, Tanzania.
Bryson Mcharo IkoshiMuhimbili Orthopaedic Institute, Muhimbili University of Health and Allied Sciences, Dar es Salaam, Tanzania.
Emmanuel Roagthe LemaMuhimbili Orthopaedic Institute, Muhimbili University of Health and Allied Sciences, Dar es Salaam, Tanzania.
Edmund Ndalama EliezerMuhimbili Orthopaedic Institute, Muhimbili University of Health and Allied Sciences, Dar es Salaam, Tanzania.
Patricia RodarteInstitute for Global Orthopaedics and Traumatology, Department of Orthopaedic Surgery, University of California, San Francisco, CA, USA.
Mayur UrvaInstitute for Global Orthopaedics and Traumatology, Department of Orthopaedic Surgery, University of California, San Francisco, CA, USA.
Jamieson O'MarrInstitute for Global Orthopaedics and Traumatology, Department of Orthopaedic Surgery, University of California, San Francisco, CA, USA.
John IbrahimInstitute for Global Orthopaedics and Traumatology, Department of Orthopaedic Surgery, University of California, San Francisco, CA, USA.
Coleen SabatiniInstitute for Global Orthopaedics and Traumatology, Department of Orthopaedic Surgery, University of California, San Francisco, CA, USA.
David ShearerInstitute for Global Orthopaedics and Traumatology, Department of Orthopaedic Surgery, University of California, San Francisco, CA, USA.
Saam MorshedInstitute for Global Orthopaedics and Traumatology, Department of Orthopaedic Surgery, University of California, San Francisco, CA, USA.
Patrick F CurranInstitute for Global Orthopaedics and Traumatology, Department of Orthopaedic Surgery, University of California, San Francisco, CA, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Femur fractures are a common cause of disability of children in low-and middle-income countries (LMICs). The introduction of flexible intramedullary nails improved the care of children with diaphyseal femoral fractures. Application of intramedullary nails is challenging in resource-limited settings due to implant cost and availability. Intramedullary Kirschner-wire (K-wire) fixation has been proposed as a low-cost alternative option for pediatric femur fractures. This study examines the non-inferiority of intramedullary K-wire to titanium elastic nail (TEN) for diaphyseal pediatric femur fractures. Methods: A randomized clinical trial was performed at a tertiary orthopaedic center in Dar es Salaam, Tanzania. Children (5-14 years) with acute diaphyseal femur fractures were randomly assigned to intramedullary K-wire or TEN fixation. The primary outcome was malunion. Secondary outcomes included modified RUST score (mRUST), PedsQL questionnaire, squat depth, and complications. Results: Of the 61 patients (33 K-wire, 28 TEN), 83% completed 1-year follow-up. This trial enrolled 61 of 160 planned patients (38% of target enrollment) and was therefore underpowered to establish non-inferiority. There were 5 cases of malunion (3 K-wire, 2 TEN; Risk difference 0.034, 95% CI -0.122-0.191, Conclusions: This study is the first prospective RCT assessing intramedullary K-wire versus TEN for the treatment of pediatric femoral shaft fractures in Africa. No statistically significant difference was detected in malunion, radiographic union, functional outcomes, or patient/parent reported outcome measures between groups. Although this study did not achieve its target sample size and therefore cannot formally claim non-inferiority, non-inferiority was not established. A trend toward higher reoperation rates in the K-wire group (9% vs. 0%) warrants evaluation in adequately powered future trials. Intramedullary K-wires may be considered as an alternative implant when TEN is unavailable, but the current evidence is insufficient to support a recommendation of equivalence. Key Concepts: (1)Intramedullary K-wire fixation showed no statistically significant difference in rates of malunion, radiographic union, and functional outcomes compared to titanium elastic nails for pediatric diaphyseal femur fractures in a low-resource setting; however, the study was underpowered and non-inferiority was not formally established.(2)Two independent randomized controlled trials, conducted on two different continents, have found no statistically significant difference in outcomes between intramedullary K-wires and titanium elastic nails for pediatric femoral shaft fractures, at a fraction of the implant cost, supporting their role as a viable alternative in resource-limited settings.(3)Although this study did not achieve its target sample size and therefore cannot formally claim non-inferiority, the results are consistent with K-wires being a safe and effective alternative to titanium elastic nails.(4)The substantial cost advantage of K-wires supports their use as a strategy to expand access to operative fixation in low- and middle-income countries.(5)Patient-reported and functional outcomes, including PedsQL quality-of-life scores and squat depth, showed no statistically significant difference between K-wire and titanium elastic nail groups at one-year follow-up; however, the study was underpowered, and these findings should be interpreted accordingly. Level of Evidence: Level I.

Indexed as

Intramedullary fixationKirschner wireLow- and middle-income countriesPediatric femur fractureTitanium elastic nail

Identifiers

PMID42598565
PMCPMC13471317

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.