Evidence map›Paper›PMID 42597877›Full record

ArticleOrthopaedic journal of sports medicine2026

Posterior Plate Positioning Without Distal Placement in Medial Closing-Wedge Distal Femoral Osteotomy.

Hyun-Soo Moon, Hyoung-Taek Hong, Min Jung, Kwangho Chung, Se-Han Jung, Jun-Hee Cho, Min-Ho Lee, Kyoung-Tak Kang, Sung-Hwan Kim

Abstract read
In one paragraph

Article in Orthopaedic journal of sports medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Hyun-Soo MoonArthroscopy and Joint Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0001-8678-2960
Hyoung-Taek HongSkyve R&D LAB, Skyve Co, Ltd, Seoul, Republic of Korea.
Min JungArthroscopy and Joint Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0002-7527-4802
Kwangho ChungArthroscopy and Joint Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea.
Se-Han JungArthroscopy and Joint Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0001-8422-093X
Jun-Hee ChoArthroscopy and Joint Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea.
Min-Ho LeeSkyve R&D LAB, Skyve Co, Ltd, Seoul, Republic of Korea.
Kyoung-Tak KangSkyve R&D LAB, Skyve Co, Ltd, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0002-6752-4576
Sung-Hwan KimArthroscopy and Joint Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0001-5743-6241

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Despite efforts to improve mechanical stability and reduce complications after medial closed-wedge distal femoral osteotomy (MCDFO), the role of plate positioning in determining mechanical stability remains unclear. Purpose: To determine the biomechanically optimal plate position during MCDFO using finite element analysis (FEA). Study Design: Descriptive laboratory study. Methods: Five distinct 3-dimensional finite element models of the distal femur and implant (TomoFix Medial Distal Femur Plate and screws) were developed from computed tomography data, and a virtual MCDFO was performed. To identify the biomechanically optimal implant positioning, nine unique configurations were created by systematically varying the plate height (proximal-distal) and depth (anterior-posterior) in 5 mm increments. Physiological loading conditions were simulated by applying joint loads at 0°, 30°, and 90° of knee flexion. Biomechanical stability of the bone-implant construct, including the osteotomy site, was evaluated based on the following parameters: (1) micromotion at the osteotomy site, (2) mean stress applied to the bone and implant, (3) mean stress in the lateral hinge of the distal femur, and (4) peak von Mises stress (PVMS) on the plate and each screw. Results: A total of 30 analyses were conducted by performing 6 simulations for each model to meet the sample size requirement determined by a priori power analysis. Micromotion at the osteotomy site was significantly reduced with posterior and proximal plate positioning, a trend consistent across all knee flexion angles. The mean stress in the bone and implant showed no clear directional trend with plate position, whereas stress at the lateral hinge of the distal femur was lowest with posterior-middle placement and remained consistent across all flexion angles. PVMS revealed that anterior-distal placement tended to produce the highest stresses across the plate and screws-occasionally exceeding the titanium alloy's yield strength-while posterior-proximal repositioning progressively reduced them. Conclusion: Posterior plate positioning without distal placement was associated with improved biomechanical stability of the bone-implant construct during MCDFO in this FEA. Clinical Relevance: Because plate position can be readily adjusted during MCDFO, the present findings provide practical biomechanical guidance for implant placement and may help reduce mechanical complications associated with the procedure.

Indexed as

distal femoral osteotomyfinite element analysismicromotionplate positionstability

Identifiers

PMID42597877
PMCPMC13469852

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.