Application of a low-cost Geiger-Müller monitoring system for clinical radiation environments.

Jungsam Choi, Chai Hong Rim, Hakyoung Kim, Wonho Lee

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Jungsam ChoiDepartment of Radiation Oncology, Korea University Guro Hospital, Korea University College of Medicine, Seoul, Republic of Korea.
Chai Hong RimDepartment of Radiation Oncology, Korea University Ansan Hospital, Korea University College of Medicine, Seoul, Republic of Korea.
Hakyoung KimDepartment of Radiation Oncology, Korea University Guro Hospital, Korea University College of Medicine, Seoul, Republic of Korea.
Wonho LeeSchool of Health and Environmental Science, Korea University, Seoul, Republic of Korea.

Funding

Korean government RS-2024-00334576Korean government RS-2025-02303227National Research Foundation of Korea
6 · The paper itself

Abstract

backgroundLow-cost Geiger-Müller detectors may support clinical radiation monitoring, but their response varies with radiation type and measurement conditions. PURPOSE: To evaluate an Arduino-based Geiger-Müller monitoring system in representative clinical radiation environments and determine whether condition-specific calibration reduces disagreement with a reference survey meter.

methodsThe system was compared with a reference energy-compensated Geiger-Müller survey meter (Ludlum Model 3005) under computed tomography scatter, Ir-192 brachytherapy, and 6 MV linear accelerator maze conditions. Calibration coefficients, expressed as counts per minute (CPM) per µSv/h, were estimated using zero-intercept regression, and method agreement was assessed using bias analysis and Bland-Altman plots. Portable deployment and user acceptability were also evaluated. The effective dead time of the counting chain was estimated using the first-order two-source approximation, and the intrinsic photon energy response was characterized using discrete-energy gamma-emitting sources (Co-57, Cs-137, and Co-60). Calibration-coefficient stability was also assessed at a fixed maze position across nominal dose rates of 100-600 MU/min to isolate count-rate effects.

resultsCalibration coefficients ranged from 124 to 133 for computed tomography scatter, 99 to 179 for Ir-192, and 145 to 233 for the 6 MV linear accelerator maze, demonstrating marked condition dependence. Applying condition-specific calibration reduced systematic bias within the evaluated environments. The effective dead time was approximately 258 µs, and the detector showed greater response per unit dose at lower photon energies, consistent with the known energy dependence of uncompensated Geiger-Müller tubes and providing a plausible explanation for the condition-dependent calibration coefficients. At a fixed maze position, the calibration coefficient varied little across nominal dose rates of 100-600 MU/min (coefficient of variation, 3.04%), with no evidence that count-rate dependence dominated within this range. In the linear accelerator maze, mean bias approached zero after distance-specific calibration, whereas the limits of agreement widened with increasing distance. Among 27 respondents, intention for continued use was more strongly associated with perceived stability and lower perceived risk than with numerical agreement alone.

conclusionsWith condition-specific calibration, the low-cost monitoring system showed low mean bias relative to the reference instrument in the evaluated low-to-moderate dose-rate clinical environments. These findings support further evaluation of the system as a supplementary tool for routine radiation monitoring and safety checks under comparable clinical conditions.

Indexed as

Particle AcceleratorsPhantoms, ImagingRadiation MonitoringBrachytherapyCalibrationHumansIridium RadioisotopesTomography, X-Ray ComputedIridium Radioisotopescalibration coefficientGeiger–Müller detectorradiation monitoringradiation protectionsurvey meter

Identifiers

PMID42596075
PMCPMC13473700

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.