Evidence map›Paper›PMID 42596016›Full record

ArticleScandinavian journal of trauma, resuscitation and emergency medicine2026

Ambient oxygen enrichment during cardiopulmonary resuscitation: an overestimated risk? - Insights from a manikin study.

Dominik J Hoechter, Florian Pfeiffer, Michael Storz, Andreas Higl, Bjarne Schmalbach, Katja Petrowski, Tobias Achtsnit

Abstract read
In one paragraph

Article in Scandinavian journal of trauma, resuscitation and emergency medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Dominik J HoechterDepartment of Anaesthesiology, LMU University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany. dominik.hoechter@med.uni-muenchen.de.ORCID https://orcid.org/0000-0003-4026-5137
Florian PfeifferDepartment of Anaesthesiology, LMU University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany.
Michael StorzCity of Munich, Fire Department, Vocational School for Emergency Paramedics, An der Hauptfeuerwache 8, 80331, Munich, Germany.
Andreas HiglCity of Munich, Fire Department, Analytical Task Force & Center of Excellence for CBRN-Protection, An der Hauptfeuerwache 8, 80331, Munich, Germany.
Bjarne SchmalbachMedical Psychology and Medical Sociology, University Medical Center of the Johannes Gutenberg University Mainz, Saarstraße 21 (Campus Universität), 55099, Mainz, Germany.
Katja PetrowskiMedical Psychology and Medical Sociology, University Medical Center of the Johannes Gutenberg University Mainz, Saarstraße 21 (Campus Universität), 55099, Mainz, Germany.
Tobias AchtsnitCity of Munich, Fire Department, Analytical Task Force & Center of Excellence for CBRN-Protection, An der Hauptfeuerwache 8, 80331, Munich, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND/

aimTo reduce the risk of fire, the ERC resuscitation guidelines recommend removing all oxygen-delivery devices at least 1 m away from the patient's chest prior to defibrillation. This recommendation is based on the assumption of relevant local oxygen accumulation. The presented study aimed to characterise ambient oxygen concentrations during cardiopulmonary resuscitation (CPR) and to assess the effect of removing oxygen-delivery devices.

methodsIn a controlled mannequin-based simulation study, 20 resuscitation scenarios were performed under standardised conditions, varying oxygen delivery, airway management, ventilation mode, environment (room vs. ambulance), and distance of oxygen sources. Oxygen concentrations were continuously measured and recorded at 10-second intervals at three locations corresponding to typical defibrillation sites. Linear mixed-effects models were used to analyse predictors of oxygen fraction.

resultsA total of 6,555 oxygen measurements were recorded. Median oxygen concentration was 21.6% (IQR 21.3-22.1%). Removing oxygen delivery devices to > 1 m did not result in lower oxygen concentrations compared with leaving them in proximity of the mannequin's head. Endotracheal intubation compared to an open airway and the use of an OxyDemand valve compared to a reservoir with 15 L/min oxygen flow were associated with slightly lower oxygen fractions, whereas other factors (handling of upper garments, site, use of mechanical CPR) showed no clinically relevant effects.

conclusionClinically relevant oxygen accumulation at defibrillation sites was not observed. Likewise, removing oxygen-delivery devices did not result in a reduction in oxygen concentrations. Under the tested conditions, these findings do not support clinically relevant oxygen enrichment during CPR, questioning the risk of oxygen-enriched atmospheres during CPR as well as the role of routine removal of oxygen sources prior to defibrillation.

Indexed as

Cardiopulmonary ResuscitationFiresManikinsOxygenHumansOxygenCardiopulmonary resuscitationCombustionCPRDefibrillationFire hazardOxygen

Identifiers

PMID42596016
PMCPMC13474727

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.