Evidence map›Paper›PMID 42593563›Full record

ArticleJournal of robotic surgery2026

Comparative evaluation of CT-to-Fluoroscopy and Scan-and-Plan registration techniques in robot-assisted pedicle screw placement: a preliminary cadaveric faesibility study.

Jacob Oh, Monchai Ruangchainikom, Satish Kripalani, S Vidyadhara, Saw Lim Beng, Wayne Ming Quan Yap, Jitesh Manghwani, Mirant Dave, H S Chhabra

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Journal of robotic surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Jacob OhDepartment of Orthopaedic Surgery, Tan Tock Seng Hospital, Singapore, Singapore.
Monchai RuangchainikomFaculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand.
Satish KripalaniSpine Services, Sri Balaji Action Medical Institute, New Delhi, India.
S VidyadharaManipal Hospitals, Bengaluru, India.
Saw Lim BengDepartment of Orthopaedic Surgery, Sunway Medical Centre, Chennai, India.
Wayne Ming Quan YapDepartment of Orthopaedic Surgery, Tan Tock Seng Hospital, Singapore, Singapore.
Jitesh ManghwaniOrthopaedic Spine Surgery, Max Shalimar Bag, New Delhi, India.
Mirant DaveStavya Spine Hospital and Research Institute, Ahmedabad, India.
H S ChhabraDepartment of Spine and Rehabilitation Centre, Sri Balaji Action Medical Institute, New Delhi, India. hschhabrascientific@gmail.com.ORCID http://orcid.org/0000-0001-5519-9609

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

STUDY

designPreliminary Cadaveric Faesibility study. PURPOSE: To evaluate the preliminary faesibility, technical accuracy, and procedural metrics of CT-to-Fluoroscopy and Scan-and-Plan registration techniques in robot-assisted pedicle screw placement using the Mazor X robotic system.

backgroundRobot-assisted pedicle screw placement has been associated with improved accuracy and safety compared with conventional freehand techniques. However, direct comparisons between the two commonly used robotic registration workflows-CT-to-Fluoroscopy and Scan-and-Plan-remain limited. Evaluating their relative performance is important for optimizing surgical workflow and radiation utilization. METHODOLOGY: Four fresh-frozen male cadavers were allocated to CT-to-Fluoroscopy (n = 2) or Scan-and-Plan (n = 2) registration groups. Eight experienced spine surgeons inserted a total of 32 pedicle screws bilaterally from L2 to L5. Screw accuracy was assessed using the Gertzbein-Robbins classification and trajectory deviation analysis in axial, sagittal, and coronal planes. Procedural time, surgeon-reported ease of use, and radiation exposure were also evaluated.

resultsAll 32 screws were clinically acceptable (Grade A + B), resulting in 100% overall accuracy in both groups. CT-to-Fluoroscopy demonstrated a higher proportion of Grade A screws than Scan-and-Plan (87.5% vs. 50.0%; p = 0.054). Scan-and-Plan showed significantly lower sagittal angular deviation (0.55 ± 0.71° vs. 1.66 ± 1.14°; p = 0.002), superior clearance (0.20 ± 0.16 mm vs. 0.45 ± 0.36 mm; p = 0.038), and lower coronal angular deviation (0.59 ± 0.76° vs. 1.99 ± 1.74°; p = 0.002). Planning, execution, and overall procedure times were comparable between groups, although Scan-and-Plan required shorter registration time. Surgeon satisfaction was identical (4.75 ± 0.46). Radiation exposure to surgeons was negligible in both groups, while cadaver radiation exposure was higher with CT-to-Fluoroscopy.

conclusionBoth registration workflows achieved excellent accuracy. Scan-and-Plan demonstrated advantages in registration efficiency and patient-equivalent radiation exposure while maintaining comparable procedural performance, supporting its use when workflow optimization and radiation reduction are priorities.

Indexed as

Pedicle ScrewsRobotic Surgical ProceduresTomography, X-Ray ComputedCadaverFluoroscopyHumansLumbar VertebraeMaleRobot-assisted pedicle screw placement; CT-to-Fluoroscopy registration; Scan-and-plan registration; Spinal robotics; Pedicle screw accuracy

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.