Evidence map›Paper›PMID 42592108›Full record

ArticleMeasurement science & technology2026

Mechanically-induced fiducial marker system for event-based synchronization of independent recording instruments.

Kourosh Kalayeh, John O L DeLancey, James A Ashton-Miller, J Brian Fowlkes

Abstract read
In one paragraph

Article in Measurement science & technology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Kourosh KalayehDepartment of Radiology, University of Michigan, Ann Arbor, MI, United States of America.ORCID https://orcid.org/0000-0002-5254-6705
John O L DeLanceyDepartment of Urology, University of Michigan, Ann Arbor, MI, United States of America.ORCID https://orcid.org/0000-0002-1012-7713
James A Ashton-MillerDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, MI, United States of America.ORCID https://orcid.org/0000-0003-1528-2787
J Brian FowlkesDepartment of Radiology, University of Michigan, Ann Arbor, MI, United States of America.ORCID https://orcid.org/0000-0002-4536-3919

Funding

Development of 21st Century Concepts and Tools for Quantifying Urethral Failure Mechanisms that Cause Urinary IncontinenceRC2DK122379 · NIDDK · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI ASHTON-MILLER, JAMES ANTHONY, DELANCEY, JOHN O.L. · 2019 to 2024
$5.7M
NIDDK NIH HHS RC2 DK122379
6 · The paper itself

Abstract

Many experimental and clinical measurements require simultaneous acquisition from independent instruments that do not share a clock. We describe a device that enables such pairings via event-based synchronization: an electrical trigger from one instrument drives an Arduino-controlled stepper actuator that produces a brief mechanical event at a location sensed by the other instrument, leaving a fiducial marker for post-hoc temporal alignment. The motivating application is synchronization of high-resolution manometry (HRM) with transperineal ultrasound for phenotyping stress urinary incontinence. Bench characterization yielded a device latency of

Indexed as

event-based synchronizationfiducial markerhigh-resolution manometry (HRM)pelvic floor disordersstress urinary incontinence (SUI)transperineal ultrasound (TPUS)

Identifiers

PMID42592108
PMCPMC13463179

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials