Evidence map›Paper›PMID 42592096›Full record

ReviewAnnals of intensive care2026

Airway tracers and biomarkers for aspiration detection and VAP prediction in ICU patients with tracheal tubes: a systematic review and diagnostic accuracy meta-analysis.

Suwen Li, Chenxin Ye, Luying Chen, Yuting Wu, Gendi Lu

Abstract readReview
In one paragraph

Review in Annals of intensive care, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Suwen LiShanghai Shuguang Hospital Affiliated with Shanghai University of TCM, Clinical Research Center, Shanghai, 201203, China.
Chenxin YeShanghai Shuguang Hospital Affiliated with Shanghai University of TCM, Clinical Research Center, Shanghai, 201203, China.
Luying ChenShanghai Shuguang Hospital Affiliated with Shanghai University of TCM, Clinical Research Center, Shanghai, 201203, China.
Yuting WuShanghai Shuguang Hospital Affiliated with Shanghai University of TCM, Clinical Research Center, Shanghai, 201203, China.
Gendi LuShanghai Shuguang Hospital Affiliated with Shanghai University of TCM, Clinical Research Center, Shanghai, 201203, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Ventilator-associated pneumonia (VAP) remains an important complication in mechanically ventilated patients in intensive care units (ICUs). Early subglottic microleakage may precede overt infection but remains difficult to detect at the bedside. Airway tracers and biochemical biomarkers have been proposed as bedside tools for detecting upstream microleakage and predicting downstream VAP, but their diagnostic value remains uncertain because studies differ in sampling matrices, thresholds, reference standards, and endpoints. Methods: Six databases were systematically searched from inception to 1 March 2026. Studies evaluating airway tracers or biomarkers in critically ill adults receiving invasive mechanical ventilation or with artificial airways were included under a dual-endpoint framework, comprising upstream microleakage or aspiration-related event detection and downstream VAP prediction. Study data were extracted, and risk of bias was assessed using the QUADAS-2 tool. For markers with sufficient clinical and methodological comparability, quantitative analyses included bivariate random-effects pooling, variance decomposition, stepwise sensitivity analyses, and Bayes' theorem-based post-test probability projection. Results: Sixteen studies were included. Blue-dye-based visual methods were summarized descriptively because the available studies represented distinct aspiration paradigms and did not meet the criteria for quantitative pooling. FEES-validated tracheostomy studies reported relatively high sensitivity for swallowing-related transglottic aspiration, whereas enteral-tracer or reflux-aspiration monitoring studies were limited by surrogate reference standards and/or low visual detectability for continuous, low-volume microleakage. One mechanically ventilated enteral-feeding cohort was retained as narrative evidence only because it did not provide a direct 2 × 2 diagnostic accuracy comparison of visual blue-dye detection against the microsphere reference standard. For VAP prediction, airway α-amylase showed a pooled sensitivity of 78.1%, specificity of 70.3%, and an area under the curve of 0.811. Conclusions: Current airway tracers and biomarkers do not appear suitable as standalone diagnostic triggers for VAP. However, airway α-amylase may have potential as a negative-predictive screening tool. Future research should standardize volumetric airway sampling and prospectively validate clinically actionable rule-out algorithms to support early antimicrobial de-escalation.

Indexed as

BiomarkersDiagnostic accuracyMeta-analysisMicroaspirationVentilator-associated pneumonia

Identifiers

PMID42592096
PMCPMC13463812

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.