Evidence map›Paper›PMID 42591821›Full record

ArticleAnnals of joint2026

Hip resurfacing arthroplasty with cemented highly cross-linked all polyethylene acetabular components.

James W Pritchett

Abstract read
In one paragraph

Article in Annals of joint, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

James W PritchettDepartment of Orthopedic Surgery, Swedish Medical Center, Seattle, WA, USA.ORCID https://orcid.org/0000-0003-3088-9616

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Hip resurfacing arthroplasty (HRA) is needed for certain patients, such as those with in situ metal work and abnormal anatomy, and/or other needs that are not well-served by total hip replacement (THR). Over the last 20 years, almost all HRAs have been performed using Metal-on-Metal (MoM) bearings, but metal wear debris generated over time has now ended their continued use. Cemented highly cross-linked polyethylene (XLPE) acetabular bearings have shown excellent survivorship for use in THR and the aim of this study is to determine if this also applied to HRA. Methods: This prospective cohort study evaluated extending the use of cemented XLPE acetabular bearings to HRA. There were 122 HRA patients who received a cemented XLPE acetabular component. They were followed for a mean 15 years (range, 10-20 years). There were 65 women (53%) and 57 men (47%). The mean age at surgery was 49.2 years (range, 21-68 years) the mean body mass index (BMI) was 26 kg/m Results: The 10-year survival rate for 122 hips was 93.5% [95% confidence interval (CI): 91.7-98.1%] for all-cause revision. Six acetabular bearings failed, requiring revision for: loosening [2], polyethylene wear [2], and dislocation [2]. Four additional well-functioning XLPE bearings were retrieved postmortem. Two well-functioning cemented acetabular bearings were also retrieved; one was an explant for an infection after 9 years and the other was retrieved during revision to THR because of femoral head avascular necrosis at 6 years. Analysis of the 12 retrievals found signs of limited anterior/superior wear in all bearings along with minimal wear in the dome of 10 bearings. Only two retrieved bearings had more than 50% of the anterior/superior area worn and these were after 15 and 20 years of use. Two of the retrieved implants had no signs of wear. Conclusions: Cemented all XLPE acetabular bearings produced successful clinical outcomes initially in all patients. Six (4.9%) patients required revision for acetabular failure. Anterior/superior wear was found in the retrievals, but dome wear was limited. Cementing an XLPE acetabular component is a reasonable approach in HRA, but since it does not allow adjunct screw fixation that a metal-backed two-piece component can offer, it is not a solution for every HRA.

Indexed as

cemented acetabular componenthighly cross-linked polyethylene (XLPE)Hip resurfacing arthroplasty (HRA)implant survivorship

Identifiers

PMID42591821
PMCPMC13462365

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.