ArticlePhotoacoustics2026
Rapid photoacoustic trace gas sensor for online end-tidal CO monitoring in exhaled breath.
Article in Photoacoustics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Online detection of exhaled breath biomarkers has attracted increasing attention because of its noninvasive, real-time, and point-of-care diagnostic potential. End-tidal carbon monoxide (ETCO) is an important breath biomarker associated with smoking behavior, neonatal hemolysis, and cardiovascular diseases. Here, we report a differential photoacoustic spectroscopy (PAS) sensor for rapid and highly sensitive online ETCO monitoring. A compact 3D-printed dual-channel differential resonant photoacoustic cell (DPAC), with an effective sample volume of only 2.5 mL, was developed to enhance acoustic signal collection while suppressing common-mode noise. The optimized DPAC exhibited an acoustic resonance frequency of 3726.94 Hz, corresponding to a laser current modulation frequency of 1863.47 Hz for second-harmonic detection, with a quality factor of 26. A quantum cascade laser targeting the CO absorption line at 2176.1 cm
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.