Evidence map›Paper›PMID 42591261›Full record

ArticleFrontiers in medical technology2026

Prediction of catheter navigation difficulty during mechanical thrombectomy using CTA-based carotid siphon morphometry.

Ferenc Dezső Bakó, Attila Tanács, József Tolnai, Pál Barzó, Tamás Németh, Attila Nagy

Abstract read
In one paragraph

Article in Frontiers in medical technology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ferenc Dezső BakóDepartment of Medical Physics and Informatics, University of Szeged, Szeged, Hungary.
Attila TanácsDepartment of Image Processing and Computer Graphics, Institute of Informatics, University of Szeged, Szeged, Hungary.
József TolnaiDepartment of Medical Physics and Informatics, University of Szeged, Szeged, Hungary.
Pál BarzóDepartment of Neurosurgery, University of Szeged, Szeged, Hungary.
Tamás NémethDepartment of Neurosurgery, University of Szeged, Szeged, Hungary.
Attila NagyDepartment of Medical Physics and Informatics, University of Szeged, Szeged, Hungary.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Successful catheter navigation through the carotid siphon remains a major technical challenge during mechanical thrombectomy for acute ischemic stroke. Unfavorable vascular anatomy may require stepwise device escalation, prolonging procedural time and potentially delaying reperfusion. Because conventional two-dimensional measurements may not fully capture the three-dimensional vascular features influencing device behavior, this study evaluated whether CTA-derived carotid siphon morphometry can predict the level of device support required for aspiration catheter navigation. Methods: This retrospective study included patients who underwent endovascular thrombectomy at the Department of Neurosurgery, University of Szeged, between 15 April 2020 and 16 May 2022. From an initial cohort of 160 patients, 54 CTA datasets were suitable for three-dimensional segmentation, and 53 cases were included in the final morphometric analysis. Paired native CT and CTA scans were processed using a subtraction-based workflow in 3D Slicer, followed by vesselness filtering, segmentation, and centerline extraction. Local carotid siphon features, including cross-sectional area and curvature-related distance measurements, were extracted. Procedural difficulty was defined using a stepwise device-escalation scale reflecting the support required to advance the aspiration catheter through the carotid siphon. A logistic regression classifier with ridge regularization and correlation-based feature selection was trained using nine geometric attributes. Results: In the full 53-case dataset, the model achieved 58.5% accuracy, with substantial interclass overlap, particularly among higher-complexity categories. Applying a confidence-based decision criterion, retaining only predictions where the second-highest class probability was less than 60% of the highest class probability, yielded a high-confidence subset of 32 cases. In this subset, accuracy increased to 75.0%, the kappa statistic increased from 0.40 to 0.65, and the weighted F-measure reached 0.73. The model achieved 100% recall for M2 and 100% precision for M3, whereas M4 remained difficult to distinguish. Conclusion: CTA-derived three-dimensional morphometric analysis of the carotid siphon provides clinically relevant information on catheter navigation difficulty during mechanical thrombectomy. Confidence-gated classification identified anatomically well-defined cases in which device-support requirements could be predicted more reliably. Borderline cases remained influenced by factors beyond luminal geometry. Larger multicenter studies are warranted to validate this approach and assess its role in patient-specific preprocedural planning.

Indexed as

aspiration cathetercarotid siphonCT angiographydevice escalationmachine learningmechanical thrombectomymorphometry

Identifiers

PMID42591261
PMCPMC13461604

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.