Evidence map›Paper›PMID 42590742›Full record

ArticleSensors (Basel, Switzerland)2026

Unsupervised Annotation Transfer in Phase-Contrast Microscopy Using a CycleGAN.

Mokhaled N A Al-Hamadani, Stathis Hadjidemetriou, Gabor Szeman-Nagy, Paris A Skourides, Andras Hajdu, Balázs Harangi

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mokhaled N A Al-HamadaniDepartment of Data Science and Visualization, Faculty of Informatics, University of Debrecen, H-4032 Debrecen, Hungary.ORCID 0000-0002-7042-3178
Stathis HadjidemetriouDepartment of Information Technologies, University of Limassol, 3-5 Chaidariou Street, 3020 Limassol, Cyprus.ORCID 0000-0002-3205-5511
Gabor Szeman-NagyDepartment of Microbial Biotechnology and Cell Biology, University of Debrecen, Life Sciences Building 1.102, 1 Egyetem Square, H-4032 Debrecen, Hungary.
Paris A SkouridesDepartment of Biological Sciences, University of Cyprus, 1678 Nicosia, Cyprus.
Andras HajduDepartment of Data Science and Visualization, Faculty of Informatics, University of Debrecen, H-4032 Debrecen, Hungary.ORCID 0000-0003-1718-9770
Balázs HarangiDepartment of Data Science and Visualization, Faculty of Informatics, University of Debrecen, H-4032 Debrecen, Hungary.ORCID 0000-0003-4405-2040

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Domain shift between microscopy imaging domains poses a significant challenge for deploying deep learning-based cell detection models across different experimental setups. Manual annotation of new microscopy datasets remains resource-intensive and time-consuming. This study presents a detection-oriented Cycle-Consistent Generative Adversarial Network (CycleGAN)-based annotation transfer framework for adapting a labeled B16BL6 source domain to a HeLa target domain. Annotated B16BL6 melanoma microscopy images are translated into the visual appearance of HeLa microscopy data while retaining their original bounding-box annotations, enabling YOLOv8x detector training without full manual annotation of the target domain. Three YOLOv8x configurations were compared: a source-only bright B16BL6 baseline, an intensity-inverted dark B16BL6 baseline, and the proposed CycleGAN-translated B16BL6 → HeLa configuration. Performance was evaluated using standard object detection metrics on a manually annotated 100-frame HeLa target-domain subset, together with complementary unsupervised proxy metrics on the full unlabeled HeLa dataset. The CycleGAN-trained detector achieved the highest supervised target-domain performance, with a precision of 0.244, recall of 0.353, F1-score of 0.288, and mAP@0.50 of 0.186, compared with mAP@0.50 values of 0.027 and 0.009 for the bright and dark baselines, respectively. It also achieved the highest exploratory composite reliability score on the full HeLa sequence. These findings demonstrate that source-to-target image translation improves detector generalization under the investigated B16BL6 → HeLa phase-contrast microscopy domain shift, thereby reducing the need for extensive manual target-domain annotation.

Indexed as

Image Processing, Computer-AssistedAnimalsDeep LearningDetection AlgorithmsGenerative Adversarial NetworksHeLa CellsHumansMiceMicroscopy, Phase-Contrastannotation transferCycleGANdomain adaptationmicroscopy imagesunsupervised learningYOLO

Identifiers

PMID42590742
PMCPMC13468819

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.