Evidence map›Paper›PMID 42590661›Full record

ArticleSensors (Basel, Switzerland)2026

Phase-Consistency-Adaptive Multi-Path Total Focusing Ultrasonic Imaging for Delamination Quantification in L-Shaped CFRP Corner Parts.

Jie Ding, Jinming Cao, Tengfei Ma, Haodong Chen, Jun Zhang, Zheng Xu, Jiansheng Jiang, Jingli Yan, Hui Ding

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Jie DingThe School of Materials Science and Engineering, Southeast University, Nanjing 211189, China.
Jinming CaoShanghai Research Institute of Materials Co., Ltd., Shanghai 200437, China.ORCID 0009-0001-6209-620X
Tengfei MaShanghai Research Institute of Materials Co., Ltd., Shanghai 200437, China.ORCID 0009-0009-5388-7550
Haodong ChenThe School of Power and Mechanical Engineering, Wuhan University, Wuhan 430072, China.ORCID 0009-0000-8932-7365
Jun ZhangThe School of Power and Mechanical Engineering, Wuhan University, Wuhan 430072, China.ORCID 0000-0002-5213-0857
Zheng XuShanghai Research Institute of Materials Co., Ltd., Shanghai 200437, China.
Jiansheng JiangShanghai Research Institute of Materials Co., Ltd., Shanghai 200437, China.
Jingli YanThe School of Materials Science and Engineering, Southeast University, Nanjing 211189, China.
Hui DingThe School of Materials Science and Engineering, Southeast University, Nanjing 211189, China.

Funding

The National Key Research and Development Program of China 2023YFC3010300
6 · The paper itself

Abstract

The delay-and-sum total focusing method (TFM) for ultrasonic full matrix capture (FMC) depends on accurate ray path and travel time computation. In L-shaped carbon fiber-reinforced polymer (CFRP) corner parts, elastic anisotropy, multilayer stacking, and curvature-induced ray path non-uniqueness generate strong stripe-like coherent clutter (deterministic structural echoes), degrading focusing and sizing. To address this, we search multiple physically plausible candidate ray paths and propose a phase-consistency-adaptive multi-path fusion TFM (PCA-MPF-TFM) that performs pixel-wise path selection and fusion. The method is validated using pulse-echo FMC data acquired with a water-immersion linear array from a 6.4 mm-thick L-shaped CFRP specimen containing three 3 mm-diameter polytetrafluoroethylene (PTFE) inserts; the two within the concave-side inspection region were quantitatively evaluated. Compared with conventional isotropic TFM, an edge-adjacent delamination previously masked by structural noise is consistently detected with a 9.2 dB signal-to-noise ratio (SNR) and a 0.2 mm length error. For the second delamination, the SNR improves by 25 dB and the length error decreases from 0.6 mm to 0.2 mm. Experimental results demonstrate improved defect detectability and noise robustness under curved, anisotropic, and multilayer propagation while maintaining sub-millimeter sizing accuracy.

Indexed as

anisotropycarbon fiber-reinforced polymer (CFRP) compositesimage fusionray tracingtotal focusing method (TFM)

Identifiers

PMID42590661
PMCPMC13469680

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.