ArticleSensors (Basel, Switzerland)2026
Parallel-Channel PIV System for Time-Resolved Measurement of Shock Wave Reflection and Diffraction.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Conventional particle image velocimetry (PIV) techniques face an inherent trade-off between temporal resolution and single-pulse laser energy, limiting their performance in shock wave measurements. This study develops a multi-channel parallel PIV system with programmable timing control to address this constraint. By distributing laser pulses across eight independent optical channels, the system decouples single-pulse energy from the repetition rate, enabling continuous velocity field measurements at microsecond temporal resolution with high signal-to-noise ratio. Experiments were conducted on a planar shock wave propagating over a trapezoidal step in a shock tube facility. The system captured velocity fields at seven consecutive time instants with a 1 μs pulse interval, revealing the curved evolution of diffracted shock fronts and transient flow separation induced by shock-boundary-layer interaction. Comparison with unsteady Reynolds-averaged Navier-Stokes simulations demonstrated that the PIV system resolves fine-scale post-shock perturbations and turbulent fluctuations that were numerically dissipated in computational fluid dynamics. The results verify that the parallel-channel architecture accurately captures unsteady flow structures during shock reflection and diffraction, offering a reliable diagnostic technique for investigations of shock wave dynamics.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.