Evidence map›Paper›PMID 42590606›Full record

ArticleSensors (Basel, Switzerland)2026

Research on the Dielectric Constant Sensor System Based on the Short-Ended Transmission Line.

Haoyang Shi, Xuchun Zhang, Chuan Sheng, Lin Huang, Kun Wang, Xikang Li

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Haoyang ShiAir Defense and Anti-Missile Academy, Air Force Engineering University, Xi'an 710051, China.ORCID 0009-0008-0660-3677
Xuchun ZhangAir Defense and Anti-Missile Academy, Air Force Engineering University, Xi'an 710051, China.ORCID 0009-0007-7013-3502
Chuan ShengAir Defense and Anti-Missile Academy, Air Force Engineering University, Xi'an 710051, China.
Lin HuangAir Defense and Anti-Missile Academy, Air Force Engineering University, Xi'an 710051, China.
Kun WangAir Defense and Anti-Missile Academy, Air Force Engineering University, Xi'an 710051, China.ORCID 0009-0007-4253-2020
Xikang LiAir Defense and Anti-Missile Academy, Air Force Engineering University, Xi'an 710051, China.ORCID 0009-0001-8492-9188

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper presents a sensor system for measuring the dielectric constant of materials, with a control circuit, a broadband coupler and a sensing probe as its main components. The entire system can independently measure the dielectric constant of powdered solid materials and liquid materials without relying on any auxiliary equipment. According to the transmission line design theory, the sensing probe utilizes a short-ended transmission line based on air coplanar waveguide. By introducing a parallel resistor at the input of the transmission line, material under test (MUT) with different dielectric constant can directly influence the resonance frequency of the transmission line's reflection coefficient. The dielectric constant can be inverted through the measurement of the resonance frequency. This paper systematically analyzes the sufficient condition for the validity of the conclusion and discusses interference factors that may affect the measurement result, such as variation in resistor value and difference in material loss. Subsequently, a dedicated control circuit was designed and manufactured by integrating a control chip, an RF chip, and a detector, thus forming a low-cost, portable sensor system together with the sensing probe and coupler. Experimental tests were conducted on six different MUTs, and the results confirmed that the system has the capability to accurately characterize the dielectric constant of powdered solid and liquid material. Compared to other sensor systems, the proposed system features a simplified design and higher measurement precision, indicating its broad applicability in radio frequency identification.

Indexed as

dielectric constantresonance frequencysensor systemshort-ended transmission line

Identifiers

PMID42590606
PMCPMC13468929

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.