ArticleSensors (Basel, Switzerland)2026
An Inductive Sensing System for Optimizing Prosthetic Socket Fit.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Soft Mechanical Inductive Sensors: Principles, Design, and Applications.Micromachines · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This work presents the design, development, and experimental validation of an inductive sensing system for monitoring prosthetic socket fit variations caused by residual limb volume fluctuations. The system aims to reduce the risk of discomfort and tissue injury by measuring the distance between the outer rigid socket and the inner silicone elastomeric liner worn in direct contact with the residual limb. The sensing architecture consists of a portable data acquisition unit, an LC resonator sensor mounted on the inner surface of the rigid socket, and a magnetic silicone target attached to the external surface of the liner. Multiple configurations of LC resonators and magnetic targets were designed and evaluated. The results indicate that a medium-sized coil (outer diameter = 28 mm, capacitance = 181 pF) combined with a 1 mm thick silicone target made of Ecoflex™ 00-50 with 70 wt% NdFeB microparticles provides the most stable and sensitive performance. Experiments demonstrated stable distance detection up to 7 mm, with the resonant-frequency shift (relative to the baseline condition) varying from -31.37 kHz at 0 mm to -2.94 kHz at 7.00 mm, for a total shift range of 29.84 kHz. Environmental tests showed minimal drift, with frequency variations below 0.40 kHz across temperature (25-60 °C) and humidity (50-90% RH) changes. In vitro validation using a high-fidelity residual limb simulator and an adjustable socket reproduced controlled residual limb volume variations of 300 mL (i.e., +7.5%), resulting in repeatable resonant-frequency changes within 3.15-3.17 MHz with measurement variability (uA, Type A) below 0.13 kHz.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.