Evidence map›Paper›PMID 42590470›Full record

ArticleSensors (Basel, Switzerland)2026

DCPA-SNN, Direct-Coding-Physics-Aware Spiking Neural Network: A Framework for Wearable ECG Denoising Under Dynamic-Noise Conditions.

Yukun Ren, Hongyou Zuo, Yuhang Cai, Shenghua Wang, Guihao Ran, Dakun Lai

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yukun RenGlasgow College, University of Electronic Science and Technology of China, Chengdu 611731, China.ORCID 0009-0005-4965-1466
Hongyou ZuoGlasgow College, University of Electronic Science and Technology of China, Chengdu 611731, China.ORCID 0009-0003-0529-7480
Yuhang CaiGlasgow College, University of Electronic Science and Technology of China, Chengdu 611731, China.ORCID 0009-0000-2779-1015
Shenghua WangGlasgow College, University of Electronic Science and Technology of China, Chengdu 611731, China.
Guihao RanSchool of Electronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China.ORCID 0009-0007-0979-6059
Dakun LaiSchool of Electronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China.ORCID 0000-0001-9070-1721

Funding

Sichuan Science and Technology Program 2025ZNSFSC0457Student Innovation Fund of Glasgow College, UESTC none
6 · The paper itself

Abstract

Smart wearable electrocardiogram (ECG) monitoring enables continuous cardiac assessment beyond clinical settings, but ECG signals are often degraded by baseline wander, muscle artifacts, and electrode motion artifacts. At present, pure end-to-end spiking neural networks (SNNs), with the advantage of low computational complexity, have rarely been explored for ECG noise suppression, particularly under dynamic conditions. To address this gap, this study proposes Direct-Coding-Physics-Aware Spiking Neural Network (DCPA-SNN) for wearable ECG denoising. The proposed method integrates a direct-coding SNN, channel attention, residual noise learning, and a physics-aware multi-domain loss function to preserve diagnostically important waveform structures. Clean ECG signals from the MIT-BIH Arrhythmia Database and real-noise segments from the MIT-BIH Noise Stress Test Database were used to construct single-noise and mixed-noise evaluation scenarios with input SNRs ranging from -6 dB to 4 dB to reflect the noise characteristics of wearable devices. Experimental results demonstrate that DCPA-SNN achieves robust denoising performance under different noise conditions. In the mixed-noise scenario, which serves as the primary evaluation setting of this study, the average denoised SNR reached 5.80 dB, with an average SNR improvement of 6.80 dB, while the R-peak detection rate increased from 90.71% to 95.72%. These results demonstrate that the proposed model, DCPA-SNN, provides a promising approach for wearable ECG denoising with potential for low-power deployment.

Indexed as

ElectrocardiographyNeural Networks, ComputerWearable Electronic DevicesAlgorithmsArtifactsHumansSignal Processing, Computer-AssistedSignal-To-Noise Ratiodenoisingedge computingenergy consumptionspiking neural networkwearable ECG

Identifiers

PMID42590470
PMCPMC13468837

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.