Evidence map›Paper›PMID 42590461›Full record

ArticleSensors (Basel, Switzerland)2026

Design and Performance Verification of a Non-Contact Geoelectric Field Sensor Based on a Three-Layer Composite Structure.

Shaohong Wang, Da Lei, Qihui Zhen

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Shaohong WangKey Laboratory of Deep Petroleum Intelligent Exploration and Development, Institute of Geology and Geophysics, Chinese Academy of Sciences, Beijing 100029, China.ORCID 0009-0002-8528-1923
Da LeiKey Laboratory of Deep Petroleum Intelligent Exploration and Development, Institute of Geology and Geophysics, Chinese Academy of Sciences, Beijing 100029, China.ORCID 0000-0001-9687-894X
Qihui ZhenKey Laboratory of Deep Petroleum Intelligent Exploration and Development, Institute of Geology and Geophysics, Chinese Academy of Sciences, Beijing 100029, China.ORCID 0000-0003-3708-7288

Funding

Deep Earth Probe and Mineral Resources Exploration-National Science and Technology Major Project 2024ZD1002501
6 · The paper itself

Abstract

Geoelectric field observations play a vital role in geophysical exploration, geological disaster early warning, and underground resource detection. Traditional contact non-polarisable electrodes, which require burial and electrolyte coupling, are hindered by several issues, such as limited adaptability to challenging terrain, significant electrode potential drift, and high susceptibility to environmental interference. Existing non-contact electric field sensors often exhibit insufficient coupling capacitance, poor impedance matching for ultra-weak high-impedance signals, and inadequate low-frequency noise suppression, rendering them unsuitable for the precise acquisition of natural microvolt-level geoelectric field signals. To address these challenges, this study introduces an innovative non-contact geoelectric field sensor with a three-layer composite structure. The sensor operates based on the principle of a parallel-plate capacitor, with a conductive silver paste layer at the top acting as the signal acquisition electrode plate, which forms an equivalent parallel-plate capacitance model with the ground to achieve non-contact capacitive coupling for geoelectric field detection. The intermediate layer uses lead zirconate titanate (PZT) piezoelectric ceramics as a support medium with a high dielectric constant. At the bottom is a silicon-based, flexible, sensitive ground-contacting layer with high elasticity, which allows it to adapt to micro-level surface irregularities, eliminating air gaps between the electrode plate and the ground, increasing plate-to-ground coupling capacitance, and ensuring the stability of the capacitance. The three-layer structure was created using a dry-press sintering integration approach, which eliminates interlayer bonding materials while ensuring consistent dielectric performance and efficient charge transfer. Additionally, a specialised signal-conditioning circuit was designed to match the ultra-high-impedance sensitive unit, utilising the ADA4528-2 ultra-low-noise precision operational amplifier, which achieved low-loss conversion and strong noise suppression for ultra-weak high-impedance charge signals. The circuit simulation results demonstrate that the designed circuit achieves an input impedance of no less than 10 TΩ, an effective operating bandwidth from 0.02 Hz to 20 kHz, and a voltage noise density lower than 1.5 μV/√Hz at 10 Hz, fully covering the ultra-low-frequency effective band of natural geoelectric fields. Field experiments comparing artificial and natural field signals revealed that the proposed sensor could be quickly deployed by simply attaching it to the ground without burial. Its time-domain waveform consistency and frequency-domain component matching were nearly identical to those of commercial standard solid non-polarisable electrodes, with a cross-correlation coefficient greater than 0.98, indicating no significant potential drift or power-frequency interference. By structurally eliminating the inherent electrode potential difference, the sensor offers advantages such as ease of deployment, strong environmental adaptability, high precision for weak signal acquisition, and excellent engineering substitutability. It is well suited for long-term geoelectric field observations in complex field scenarios, including deserts, Gobi areas, and frozen soil regions, and provides a high-performance, novel sensing solution for geoelectric field detection in extreme environments.

Indexed as

geoelectric field observationhigh input impedancelow-noise conditioning circuitnon-contact measurement

Identifiers

PMID42590461
PMCPMC13469865

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.