Failure Analysis of Acid-Thinned Coiled Tubing Under HTBH Conditions: Role of Inhibitor Depletion and Corrosion Asymmetry.
Article in Materials (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A CT-80 coiled tubing fractured at the gooseneck during retrieval after a 2.5 h treatment with 15% HCl under high-temperature bottom-hole conditions (196 °C). The failure was investigated by dimensional measurements, metallography, Vickers microhardness testing, SEM/EDS, and FT-IR spectroscopy. Pronounced corrosion asymmetry was observed. Cumulative external wall loss reached 1.196 mm, compared with 0.292 mm on the inner wall, while the wall loss attributed to the final operation was approximately twelve times greater externally than internally. These findings suggest two different exposure histories: predominantly uniform attack of the outer wall during backflow of spent, inhibitor-depleted acid, and localized pitting of the inner wall under incomplete inhibitor coverage. EDS mapping identified Sb-rich deposits around inner-wall pits. In combination with the relevant literature, this distribution is consistent with a possible Sb-Fe galvanic effect that may have promoted local anodic dissolution, although galvanic coupling was not measured directly. The FT-IR spectra were consistent with iron oxides/oxyhydroxides, carbonate-containing scale, sulfate-bearing products on the outer surface, and thin organic residues rather than a continuous inhibitor film. Microhardness increased from 229 HV1 in the new tubing to 243.4 HV1 at the fracture location; this increase may reflect limited hydrogen uptake together with service-induced strain hardening or residual stresses. Fractography showed necking and dimpled microvoid coalescence, supporting a predominantly ductile overload mechanism in the corrosion-thinned section. A limited contribution of hydrogen to ductility loss cannot be excluded because the hydrogen content was not quantified.