Evidence map›Paper›PMID 42587285›Full record

Observational studyBMC musculoskeletal disorders2026

Early surgeon experience with a fracture-specific humeral stem for proximal humerus fractures: a multicenter survey of predominantly reverse shoulder arthroplasty cases with an illustrative case.

Matthias Regling, You Yang, Arthur de Gast, Gary F Updegrove

Abstract readMulticenter StudyObservational StudyCase Reports
In one paragraph

Observational study in BMC musculoskeletal disorders, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Matthias ReglingStryker Trauma GmbH, Prof.-Küntscher-Str. 1, Schönkirchen, 24232, Germany. matthias.regling@stryker.com.
You YangStryker Corporation, 10801 Nesbitt Avenue South, Bloomington, MN, 55437, USA.
Arthur de GastStryker European Operations Ltd, Herikerbergweg 110, Amsterdam, 1101 CM, Netherlands.
Gary F UpdegroveDepartment of Orthopaedics and Rehabilitation, Penn State Hershey Bone and Joint Institute, Penn State Milton S. Hershey Medical Center, 30 Hope Drive, Hershey, PA, 17033, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundShoulder arthroplasty has become an established treatment option for displaced and complex proximal humeral fractures, particularly in elderly patients. Fracture-specific stems are increasingly used in clinical practice; however, early data on surgeon experience with newly introduced convertible stem designs remain limited. This study aimed to assess orthopedic surgeons' early intraoperative experience with a newly developed humeral fracture system (Tornier Perform Humeral System - Fracture, Tornier Inc., a wholly owned subsidiary of Stryker, Bloomington, MN, USA) using a structured survey as part of an early product surveillance program.

methodsA prospective observational survey was conducted among orthopedic surgeons in the United States and Canada who had performed surgery using the fracture stem. Case-level evaluations of intraoperative handling, technical features, and surgeon-reported comparisons with routinely used implant systems were collected. Descriptive statistics were used to summarize survey responses.

resultsTwenty-six orthopedic surgeons submitted feedback on 47 surgical cases (45 primary cases, 2 revisions), including predominantly reverse configurations (46/47) and one hemiarthroplasty construct. All available stem fixation methods were used: cementless without interlocking screws (n = 24), cementless with interlocking screws (n = 14), and cemented (n = 9). Surgeons reported high levels of satisfaction and favorable ratings for ease of use. Across multiple comparative dimensions, the fracture system was frequently rated favorably compared with surgeons' routinely used systems. Twenty-five of 26 participating surgeons indicated that they would consider using the system in future cases and would recommend it to others (missing data for one surgeon). Qualitative feedback described perceived benefits related to specific design features, including press-fit capability, bone graft window, proximal stem design, and the option for interlocking screw fixation.

conclusionsSurgeons reported favorable early intraoperative impressions of this fracture system. These findings provide exploratory insights into surgeon-reported usability and perceived design characteristics under early real-world use. Further studies are required to evaluate the clinical relevance of these surgeon-reported perceptions. LEVEL OF EVIDENCE: IV.

Indexed as

Arthroplasty, Replacement, ShoulderOrthopedic SurgeonsShoulder FracturesShoulder ProsthesisAgedCanadaClinical CompetenceFemaleHumansMaleProspective StudiesProsthesis DesignSurveys and QuestionnairesUnited StatesHemiarthroplastyPHFProximal humerus fractureReverse shoulder arthroplastyShoulder arthroplastyTotal shoulder arthroplasty

Identifiers

PMID42587285
PMCPMC13471380

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.