Reducing RF-Induced Heating of DBS in 3 T MRI Using Dual-Role Receive Arrays as Wireless Resonators: A Simulation Study.

Zhonghao Zhang, Ming Lu, Zhengyi Lu, Yuankai Huo, Xinqiang Yan

Abstract read
In one paragraph

Article in IEEE access : practical innovations, open solutions, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Zhonghao ZhangDepartment of Electrical and Computer Engineering, Vanderbilt University, Nashville, TN 37235, USA.ORCID 0009-0004-8458-816X
Ming LuVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN 37232, USA.ORCID 0000-0003-2763-2561
Zhengyi LuDepartment of Computer Science, Vanderbilt University, Nashville, TN 37235, USA.ORCID 0009-0008-7586-6032
Yuankai HuoDepartment of Electrical and Computer Engineering, Vanderbilt University, Nashville, TN 37235, USA.ORCID 0000-0002-2096-8065
Xinqiang YanDepartment of Electrical and Computer Engineering, Vanderbilt University, Nashville, TN 37235, USA.ORCID 0000-0002-4232-3241

Funding

Integrated Next-generation RF Transmit, Receive and B0 shimming coil system for brain and spinal cord MRI at 7 TeslaR01EB031078 · NIBIB · VANDERBILT UNIVERSITY MEDICAL CENTER · PI YAN, XINQIANG · 2022 to 2025
$1.7M
Passive antennas for improved image quality in transcranial MR-guided focused ultrasoundR21EB029639 · NIBIB · VANDERBILT UNIVERSITY MEDICAL CENTER · PI YAN, XINQIANG · 2020 to 2022
$675k
Imbalanced RF Receive Coil Array for Magnetic Resonance-guided Focused Ultrasound NeuromodulationR21EB037763 · NIBIB · VANDERBILT UNIVERSITY MEDICAL CENTER · PI YAN, XINQIANG · 2025 to 2025
$481k
NIBIB NIH HHS R01 EB031078NIBIB NIH HHS R21 EB029639NIBIB NIH HHS R21 EB037763
6 · The paper itself

Abstract

Magnetic resonance imaging (MRI) scanning remains largely restricted to specific modalities, typically involving low radiofrequency (RF) power levels and stringent protocols for patients with deep brain stimulation (DBS) implants, due to safety concerns related to RF-induced heating of the implants. A 6-channel dual-role head coil array capable of modulating the electric-field (E-field) distribution was designed and evaluated using electromagnetic (EM) simulations. By optimizing the resonant frequency of each coil element during RF transmission, the transmit field was reshaped, leading to a significant reduction in RF-induced heating near the DBS lead tip. The proposed method was validated across two scenarios of increasing complexity: 1) a simple straight conductive wire for concept validation and 2) four realistic DBS leads representing complex real-world scenarios. The coil settings can be optimized either to suppress the E-field at a specific location, such as the DBS lead tip, or to suppress the peak specific absorption rate (SAR) across the entire human head. For location-specific E-field suppression, the simplified predefined-state control scheme and the fine-tuning genetic algorithm (GA)-based framework were implemented, achieving E-field reductions of 45.9% and 68.3%, respectively. For whole-head peak SAR suppression, the annealed Log-Sum-Exp (LSE)-Adaptive Moment Estimation (Adam) framework (LSE-Adam) was implemented, achieving an average 1 g SAR reduction of 72.09% across four realistic DBS lead models. The dual-role coil demonstrated a high degree of flexibility in controlling the transmit field and reducing RF-induced heating at DBS implants, offering a novel approach to mitigate RF-induced heating of the implants in MRI.

Indexed as

deep brain stimulationE-fieldMRI safetyRF-induced heatingSAR optimizationwireless resonator

Identifiers

PMID42582817
PMCPMC13459017

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.