Reducing RF-Induced Heating of DBS in 3 T MRI Using Dual-Role Receive Arrays as Wireless Resonators: A Simulation Study.
Article in IEEE access : practical innovations, open solutions, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Magnetic resonance imaging (MRI) scanning remains largely restricted to specific modalities, typically involving low radiofrequency (RF) power levels and stringent protocols for patients with deep brain stimulation (DBS) implants, due to safety concerns related to RF-induced heating of the implants. A 6-channel dual-role head coil array capable of modulating the electric-field (E-field) distribution was designed and evaluated using electromagnetic (EM) simulations. By optimizing the resonant frequency of each coil element during RF transmission, the transmit field was reshaped, leading to a significant reduction in RF-induced heating near the DBS lead tip. The proposed method was validated across two scenarios of increasing complexity: 1) a simple straight conductive wire for concept validation and 2) four realistic DBS leads representing complex real-world scenarios. The coil settings can be optimized either to suppress the E-field at a specific location, such as the DBS lead tip, or to suppress the peak specific absorption rate (SAR) across the entire human head. For location-specific E-field suppression, the simplified predefined-state control scheme and the fine-tuning genetic algorithm (GA)-based framework were implemented, achieving E-field reductions of 45.9% and 68.3%, respectively. For whole-head peak SAR suppression, the annealed Log-Sum-Exp (LSE)-Adaptive Moment Estimation (Adam) framework (LSE-Adam) was implemented, achieving an average 1 g SAR reduction of 72.09% across four realistic DBS lead models. The dual-role coil demonstrated a high degree of flexibility in controlling the transmit field and reducing RF-induced heating at DBS implants, offering a novel approach to mitigate RF-induced heating of the implants in MRI.