Evidence map›Paper›PMID 42582803›Full record

ArticleTranslational lung cancer research2026

Non-destructive three-dimensional structural assessment of transbronchial cryobiopsy specimens using phase-contrast X-ray CT: a proof-of-concept study.

Yuji Matsumoto, Akio Yoneyama, Rika Baba, Hideaki Furuse, Tatsuya Imabayashi, Shigehiro Yagishita, Takaaki Tsuchida

Abstract read
In one paragraph

Article in Translational lung cancer research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yuji MatsumotoDepartment of Endoscopy, Respiratory Endoscopy Division, National Cancer Center Hospital, Tokyo, Japan.ORCID https://orcid.org/0000-0003-0646-858X
Akio YoneyamaSAGA Light Source, Saga, Japan.
Rika BabaResearch and Development Group, Hitachi, Ltd., Tokyo, Japan.
Hideaki FuruseDepartment of Endoscopy, Respiratory Endoscopy Division, National Cancer Center Hospital, Tokyo, Japan.
Tatsuya ImabayashiDepartment of Endoscopy, Respiratory Endoscopy Division, National Cancer Center Hospital, Tokyo, Japan.
Shigehiro YagishitaDivision of Molecular Pharmacology, National Cancer Center Research Institute, Tokyo, Japan.
Takaaki TsuchidaDepartment of Endoscopy, Respiratory Endoscopy Division, National Cancer Center Hospital, Tokyo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Histopathological evaluation of lung biopsy specimens is inherently destructive and reduces the three-dimensional tissue architecture to limited two-dimensional sections. For small bronchoscopic specimens, this may compromise the optimal tissue utilization for diagnosis and molecular testing. We investigated whether synchrotron-based phase-contrast X-ray computed tomography (CT) could be used to non-destructively visualize the three-dimensional architecture of clinically obtained transbronchial cryobiopsy specimens. Methods: In this exploratory imaging study, we prospectively enrolled patients with peripheral pulmonary lesions who underwent bronchoscopy. An additional single cryobiopsy specimen was obtained and imaged using synchrotron-based phase-contrast CT. The structural features were evaluated by three blinded observers using predefined ordinal scores. Interobserver agreement was assessed using the weighted kappa and intraclass correlation coefficients. Representative cases underwent serial histological sectioning, and exploratory slow-freezing micro-CT imaging was performed on a subset. Results: Fifteen patients were included. Phase-contrast CT revealed major structural features including alveolar-like airspaces, tissue density, glandular lumina, solid nest-like structures, thickened bronchial wall structures, and calcified foci. The imaging findings generally corresponded to the histological findings. Interobserver agreement was moderate to substantial for airspace preservation and tissue density, whereas agreement was poor for glandular and solid nest-like structures. Exploratory micro-CT showed partial visualization of finer structures but was limited by image blurring and distortion. Conclusions: Synchrotron-based phase-contrast CT enabled non-destructive three-dimensional structural visualization of clinically obtained transbronchial cryobiopsy specimens. Although the current resolution remains insufficient for detailed histological classification, this study represents a proof-of-concept for the feasibility of this imaging technique rather than a clinical workflow utility.

Indexed as

Cryobiopsylung biopsynon-destructive imagingphase-contrast X-ray computed tomography (phase-contrast X-ray CT)three-dimensional imaging

Identifiers

PMID42582803
PMCPMC13458670

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.