ArticleQuantitative imaging in medicine and surgery2026

Respiratory motion-corrected quiescent period gating magnetic resonance attenuation correction (Q.MRAC) for enhancing quantitative accuracy in hepatic [18F]FDG PET/MRI: a dual-domain motion compensation study.

Hua Lin, Yu-Mei Pu, Li Li, Ming-Gang Su, Chun-Chao Xia

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Hua Lin *Department of Nuclear Medicine, West China Hospital of Sichuan University, Chengdu, China.
Yu-Mei Pu *Department of Radiology, West China Second Hospital of Sichuan University, Chengdu, China.
Li LiDepartment of Nuclear Medicine, West China Hospital of Sichuan University, Chengdu, China.
Ming-Gang SuDepartment of Nuclear Medicine, West China Hospital of Sichuan University, Chengdu, China.
Chun-Chao XiaDepartment of Radiology, West China Hospital of Sichuan University, Chengdu, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Respiratory motion-induced misalignment between positron emission tomography (PET) and magnetic resonance attenuation maps remains a critical challenge in abdominal PET/magnetic resonance imaging (PET/MRI) quantification. This study evaluated the performance of a novel dual-domain motion correction strategy combining emission-domain [quiescent phase gating PET acquisition (Q.Static)] and attenuation-domain [quiescent period gating magnetic resonance attenuation correction (Q.MRAC)] approaches in enhancing standardized uptake value (SUV) accuracy in hepatic fluorine-18 fluorodeoxyglucose ([18F]FDG) imaging. Methods: Fifty patients underwent [18F]FDG PET/MRI with two respiratory motion correction protocols: dual-domain correction (Q.Static + Q.MRAC) and conventional MRAC [conventional static PET acquisition (Static) + conventional magnetic resonance attenuation correction (C.MRAC)]. Three 3-cm-diameter spherical volumes of interest (VOIs) were positioned in the right hepatic lobe, including the upper lobe (VOI1), middle lobe (VOI2), and lower lobe (VOI3) to evaluate SUV quantification, spatial alignment of attenuation maps against end-expiratory T2-weighted imaging (T2WI), and motion correction efficacy. Analysis of variance was applied for comparisons of the mean SUV (SUV Results: VOI2 demonstrated minimal SUV variability [coefficient of variation (CV) =2.29-2.55%], validating its use as a reference region as per the relevant guidelines. Respiratory motion caused consistent SUV underestimation: VOI1 underestimation relative to VOI2 was 16.4% for Q.Static + Q.MRAC and 26.3% for Static + C.MRAC, while the maximum underestimation rate for VOI3 was 11.4% for Static + C.MRAC. Q.Static + Q.MRAC reduced VOI1 underestimation by 38.9% as compared to Static + C.MRAC (P Conclusions: Dual-domain motion correction (Q.Static + Q.MRAC) significantly improves SUV quantification accuracy in the upper lobe of right liver. These findings establish a foundation for achieving greater accuracy for tumor assessment and metabolic imaging in clinical practice through the use of [18F]FDG PET/MRI.

Indexed as

attenuation correctionhepatic imagingPositron emission tomography/magnetic resonance imaging (PET/MRI)respiratory motionstandardized uptake value quantification (SUV quantification)