Evidence map›Paper›PMID 42581354›Full record

ArticleBMC complementary medicine and therapies2026

Optimizing lumbar therapy: a biomechanical study of oblique pulling manipulation under different postures.

Yanfei Wang, Aorui Yu, Lianhai Jin, Weidong Liu, Dayu Chen, Yafei Cao, Kun Gao

Abstract read
In one paragraph

Article in BMC complementary medicine and therapies, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yanfei Wang *The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Guangzhou, Shenzhen, 518033, China.
Aorui Yu *The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Guangzhou, Shenzhen, 518033, China.
Lianhai JinThe Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Guangzhou, Shenzhen, 518033, China.
Weidong LiuThe Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Guangzhou, Shenzhen, 518033, China.
Dayu ChenThe Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Guangzhou, Shenzhen, 518033, China.
Yafei CaoThe Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Guangzhou, Shenzhen, 518033, China.
Kun GaoThe Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Guangzhou, Shenzhen, 518033, China. gk2735@gzucm.edu.cn.

Funding

Sanming Project of Medicine in ShenzhenSanming Project of Medicine in Shenzhen No.SZZYSM202211004Shenzhen Science and Technology Program No. JCYJ20210324111205015
6 · The paper itself

Abstract

backgroundWhile oblique pulling manipulation has proven to be an effective conservative treatment approach for lumbar disc herniation, it is not without limitations. One of the primary drawbacks of this technique is the potential for inaccurate localization during the procedure. This study aims to explore the effects of the oblique pulling manipulation under different lumbar postures and to characterize the resulting load distribution across different lumbar regions. METHODS/STUDY

designThis study employed a multi-modal approach combining infrared optical motion capture, finite element modeling, and biomechanical experiments. Eighteen healthy volunteers were divided into three groups for motion capture analysis of the oblique pulling manipulation at different angles. A finite element model of the lumbar spine was developed based on CT scans of a 24-year-old male volunteer and validated against existing literature. Biomechanical experiments were conducted on six cadaveric specimens using a BOSE testing machine to simulate the manipulation technique. Pressure measurements in the intervertebral discs and facet joints were obtained using a Tekscan pressure sensor.

resultsThe experimental results showed that the biomechanical effects of oblique pulling manipulation were closely related to lumbar posture. Infrared optical motion capture, finite element modeling, and biomechanical experiments consistently demonstrated posture-dependent, region-specific loading patterns, with peak forces preferentially concentrated around the L3/4 region in extension, the L4/5 region in flexion, and the L5/S1 region in excessive flexion. These findings suggest that adjusting lumbar posture may influence the regional distribution of mechanical loads and provide a biomechanical basis for posture-guided application of oblique pulling manipulation.

conclusionThese findings provide a biomechanical basis for posture-guided application of oblique pulling manipulation and may assist clinicians in selecting appropriate manipulation postures for patients with lumbar disc herniation.

Indexed as

Intervertebral Disc DisplacementLumbar VertebraeManipulation, SpinalPostureBiomechanical PhenomenaFinite Element AnalysisHumansMaleMotion CaptureRange of Motion, ArticularYoung AdultBiomechanical experimentsFinite element modelingInfrared optical motion captureLumbar disc herniationOblique pulling manipulation

Identifiers

PMID42581354
PMCPMC13465648

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.