Evidence map›Paper›PMID 42579604›Full record

ArticleJournal of medical Internet research2026

Finite State Machine-Guided Retrieval-Augmented Generation Improves Expert-Rated Acceptability of a Peripherally Inserted Central Catheter Self-Management Chatbot: Single-Center Content Validation Study.

Mangyeong Lee, Seung-Beom Cho, Jae-Wook Yu, Junghee Yoon, Jae-Boong Choi, Kyu-Hwan Jung, Juhee Cho

Abstract readValidation Study
In one paragraph

Article in Journal of medical Internet research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Mangyeong Lee *Center for Clinical Epidemiology, Samsung Medical Center, Seoul, Republic of Korea.ORCID http://orcid.org/0000-0002-6266-5978
Seung-Beom Cho *School of Mechanical Engineering, Sungkyunkwan University, Suwon, Republic of Korea.ORCID http://orcid.org/0000-0002-7431-8789
Jae-Wook YuSchool of Mechanical Engineering, Sungkyunkwan University, Suwon, Republic of Korea.ORCID http://orcid.org/0009-0008-5913-1976
Junghee YoonDepartment of Clinical Research Design and Evaluation, Samsung Advanced Institute for Health Sciences and Technology, Sungkyunkwan University, Seoul, Republic of Korea.ORCID http://orcid.org/0000-0003-1228-7435
Jae-Boong ChoiSchool of Mechanical Engineering, Sungkyunkwan University, Suwon, Republic of Korea.ORCID http://orcid.org/0000-0002-1596-8933
Kyu-Hwan JungDepartment of Medical Device Management and Research, Samsung Advanced Institute for Health Sciences and Technology, Sungkyunkwan University, Seoul, Republic of Korea.ORCID http://orcid.org/0000-0002-6626-6800
Juhee ChoDepartment of Digital Health, Samsung Advanced Institute for Health Sciences and Technology, Sungkyunkwan University, 115, Irwon-ro, Seoul, Republic of Korea, 82 234101448.ORCID http://orcid.org/0000-0001-9081-0266

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Patients with cancer undergoing long-term or vesicant chemotherapy frequently require peripherally inserted central catheters (PICCs). Due to the nature of ambulatory treatment administration, self-PICC management is essential for the continuation and completion of the planned treatment. Large language models offer potential for continuous patient support, but hallucinations and insufficient adherence to clinical protocols remain concerns. Fine-tuning (FT) and retrieval-augmented generation (RAG) improve factual grounding but cannot enforce the structured decision logic of expert-led PICC consultations, leaving the value of dialogue-control mechanisms unclear. Objective: This study is an expert-panel evaluation designed to exploratorily verify whether a finite state machine (FSM)-guided RAG architecture yields incremental gains in clinical acceptability when added on top of FT and RAG compared with simpler architectures (fine-tuned model alone; fine-tuned model with RAG). Methods: We conducted a blinded ablation comparison of three chatbot architectures sharing an identical fine-tuned GPT-4o-mini base: model 1 (fine-tuning only; FT), model 2 (FT + RAG), and model 3 (FT + RAG + FSM). Three nurses specializing in PICC management (≥10 y experience) independently evaluated responses to 43 PICC-related queries. The two-stage evaluation comprised query-level forced-choice preference and global Likert ratings across 8 predefined dimensions. Interrater agreement was quantified with Gwet AC1. Preference rates were compared with Cochran Q and pairwise McNemar tests with Bonferroni correction. Global Likert ratings were summarized descriptively across 8 predefined dimensions. Results: The FSM-guided model (model 3) was preferred in 34 of 43 scenarios (79.1%). Interrater agreement was moderate (Gwet AC1=0.58, 95% CI 0.42-0.75; P<.001). Differences in model preference were significant (Cochran Q=48.2; P<.001). Pairwise McNemar tests showed model 3 was preferred significantly more often than model 1 and model 2 (both P<.001), while model 1 versus model 2 did not differ after Bonferroni correction. For the global ratings, descriptive statistics indicated that model 3 received higher ratings than models 1 and 2 across most criteria, although it tended to receive lower ratings for efficiency, possibly reflecting its multiturn structure. In qualitative debriefing, the nurses noted occasional unnecessary conversational turns under FSM guidance. Conclusions: In this expert-panel content-validation study, the FSM-guided fine-tuned RAG model received higher expert-rated acceptability than the simpler architectures, with FSM-based dialogue control more closely aligning chatbot outputs with expert-led PICC consultation patterns. Patient-facing usability testing and multicenter validation are required before claims regarding patient safety or clinical deployment can be made.

Indexed as

Catheterization, Central VenousCatheterization, PeripheralSelf-ManagementGenerative Artificial IntelligenceHumansLarge Language Modelsconversational agentfinite state machinelarge language modelsperipherally inserted central catheterretrieval-augmented generation

Identifiers

PMID42579604
PMCPMC13460064