Evidence map›Paper›PMID 42577113›Full record

ArticleJMA journal2026

Feasibility of Contrast-Enhanced Spectral Mammography in Japan: A Pilot Study.

Yuko Ito, Tomoyuki Fujioka, Kazunori Kubota, Yuka Yashima, Anna Tabei, Haruka Tanaka, Toshihisa Ogawa, Tsuyoshi Nakagawa

Abstract read
In one paragraph

Article in JMA journal, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yuko ItoDepartment of Radiology, Dokkyo Medical University Saitama Medical Center, Koshigaya, Japan.
Tomoyuki FujiokaDepartment of Radiology, Dokkyo Medical University Saitama Medical Center, Koshigaya, Japan.
Kazunori KubotaDepartment of Radiology, Dokkyo Medical University Saitama Medical Center, Koshigaya, Japan.
Yuka YashimaDepartment of Radiology, Dokkyo Medical University Saitama Medical Center, Koshigaya, Japan.
Anna TabeiDepartment of Radiology, Dokkyo Medical University Saitama Medical Center, Koshigaya, Japan.
Haruka TanakaDepartment of Radiology, Dokkyo Medical University Saitama Medical Center, Koshigaya, Japan.
Toshihisa OgawaDepartment of Breast and Endocrine Surgery, Dokkyo Medical University Saitama Medical Center, Koshigaya, Japan.
Tsuyoshi NakagawaDepartment of Breast Surgery, Dokkyo Medical University, Mibu, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Contrast-enhanced spectral mammography (CESM) provides diagnostic capability comparable to dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI); however, in Japan, CESM is not routinely performed because the use of iodinated contrast agents for CESM is not approved. Evidence on CESM from Japan is therefore scarce. This study assessed the feasibility, diagnostic performance, and patient experience of CESM in Japanese patients with breast cancer. Methods: This study enrolled women aged 20-80 years with histologically confirmed breast cancer who were scheduled for surgery. CESM and DCE-MRI were performed within two months preoperatively. Images were independently interpreted by a breast radiologist. Tumor size, Breast Imaging Report and Data System (BI-RADS) category, and breast density were assessed and compared with postoperative pathology. Average glandular dose (AGD) and contrast-related reactions were evaluated. Patients answered questions regarding examination time, comfort, positioning, and preferred modality. Pearson correlation coefficients were calculated to assess the relationship among tumor sizes measured on CESM, DCE-MRI, and pathology. Results: A total of nine patients (11 malignant lesions) were analyzed. CESM detected 10 lesions (detection rate 90.9%) and DCE-MRI detected all lesions (100%). Tumor size measured by CESM (r = 0.95) and DCE-MRI (r = 0.94) showed strong correlation with pathology. AGD averaged 3.1 mGy, and no allergic reactions occurred. Patients preferred CESM primarily due to shorter examination time, while noise and long duration were the main disadvantages of DCE-MRI. Conclusions: CESM demonstrated high diagnostic performance that was comparable to DCE-MRI and superior to mammography, particularly for dense breasts. Considering its shorter examination time and favorable patient acceptance, CESM may serve as a valuable diagnostic option in Japan, thus warranting further clinical research.

Indexed as

breast cancercontrast agentcontrast-enhanced spectral mammography (CESM)dense breastmagnetic resonance imaging (MRI)mammography

Identifiers

PMID42577113
PMCPMC13453645

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.