Evidence map›Paper›PMID 42576505›Full record

ArticleNan fang yi ke da xue xue bao = Journal of Southern Medical University2026

[Motion parameter decoupling and motion constraint-driven optimization for correcting rigid motion artifacts in cone-beam computed tomography].

Haotao Jiang, Yongbo Wang, Zhaoying Bian

Abstract readEnglish Abstract
In one paragraph

Article in Nan fang yi ke da xue xue bao = Journal of Southern Medical University, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Haotao JiangSchool of Biomedical Engineering//Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou 510515, China.
Yongbo WangSchool of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, China.
Zhaoying BianSchool of Biomedical Engineering//Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou 510515, China.

Funding

National Natural Science Foundation of China 62571422
6 · The paper itself

Abstract

objectivesTo solve the problem of rigid motion artifacts caused by patient movement and gantry vibration during long-duration cone-beam computed tomography (CBCT) using geometric parameter decoupling and motion-constrained optimization.

methodsUsing a motion estimation framework based on 3D-2D rigid registration, the rigid motion parameters were categorized into out-of-plane and in-plane motions, and a stepwise optimization sequence was designed to decouple the mutual interference among the parameters. In response to dynamic evolution of artifact characteristics from multi-contour overlap to edge blurring during the iterative process, a progressive cost function was formulated to facilitate an adaptive transition of the optimization objective from projection data consistency constraints to structural detail recovery. To address the issue of multi-solution in 3D-2D registration and the potential spatial misalignment introduced during iteration, a motion estimation constraint mechanism was incorporated to eliminate global bias, thereby enhancing the algorithm's convergence.

resultsThe proposed algorithm accurately estimated rigid motion trajectories and restored the images via motion compensation. On head simulation data, this model achieved optimal quantitative metrics across 3 motion levels, improved PSNR by 2.1% and SSIM by 2.9%, and reduced RMSE by 6.5% compared to the suboptimal methods. Additional validation on knee simulation and real porcine data further demonstrated its efficacy and generalization capability.

conclusionsThe proposed rigid motion artifact correction algorithm demonstrates good performance in estimating motion trajectories and compensating for image artifacts, thus providing a viable and robust solution for suppressing rigid motion artifacts in clinical CBCT imaging.

Indexed as

ArtifactsCone-Beam Computed TomographyAlgorithmsHumansImaging, Three-DimensionalMotion3D-2D rigid registrationcone-beam computed tomographymotion constraintparameter decouplingrigid motion artifact correction

Identifiers

PMID42576505
PMCPMC13458588

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.