Evidence map›Paper›PMID 42572606›Full record

ArticleRomanian journal of ophthalmology

Scleral suture fixation of a foldable intraocular lens without a scleral flap or groove.

Hasan Burhanettin Kaptı, Kader Kasar

Abstract read
In one paragraph

Article in Romanian journal of ophthalmology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Hasan Burhanettin KaptıDepartment of Ophthalmology, Ordu University, Faculty of Medicine, Ordu, Turkey.
Kader KasarDepartment of Ophthalmology, Ordu University, Faculty of Medicine, Ordu, Turkey.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: This study aims to assess the surgical and visual outcomes of a sutured intraocular lens (IOL) fixation approach performed without creating a scleral flap or tunnel in aphakic eyes without posterior capsule support. Methods: In this retrospective study, we evaluated aphakic patients who underwent surgery using the ab externo scleral fixation technique that involved tying IOL fixation sutures on the sclera and placing the suture ends under the Tenon's capsule without opening the scleral flap. Preoperative and postoperative visual acuity, refraction values, intraocular lens centralization, and operation-related complications were analyzed. Results: In the study involving 38 patients with an average follow-up period of 8.2 months, the best-corrected visual acuity (BCVA) improved from an average of 1.00 logMAR to 0.10 logMAR. Spherical equivalent refraction decreased from +10.03 D to +0.96 D. Intraocular lens decentration was observed in 7.9% of cases. No intraoperative complications were observed, while 5.2% of patients experienced postoperative corneal edema and 2.6% experienced macular edema. Discussion: The results of this study demonstrate that the ab externo scleral fixation technique without a scleral flap or groove is a safe and effective approach for secondary IOL implantation in aphakic eyes. The significant improvement in BCVA (from 1.00 to 0.10 logMAR) and the substantial reduction in spherical equivalent refraction confirm the technique's optical efficacy. The low rates of intraoperative and postoperative complications, along with satisfactory IOL centration in 92% of cases, support the safety profile of this method. By positioning the suture ends beneath Tenon's capsule rather than creating a scleral flap or tunnel, this technique reduces operative complexity. It minimizes the risk of suture exposure and conjunctival erosion, while maintaining reliable IOL fixation. Conclusions: Due to its short surgical length, low complication rate, and satisfactory visual results, this simplified sutured IOL fixing technique without a scleral flap or tunnel is safe and effective. Suture exposure is reduced, and the procedure is less invasive, with the suture ends under Tenon's capsule. Larger, comparable, and prospective research is needed to assess the method's long-term effects.

Indexed as

Aphakia, PostcataractLenses, IntraocularLens Implantation, IntraocularScleraSurgical FlapsSuture TechniquesVisual AcuityAdultAgedFemaleFollow-Up StudiesHumansMaleMiddle AgedProsthesis DesignRefraction, OcularACIOL = Anterior chamber intraocular lensaphakiaAS-OCT = Anterior segment optical coherence tomographyBCVA = Best-corrected visual acuityCME = Cystoid macular edemaIFIOL = Iris fixated intraocular lensintraocular lensIOL = Intraocular lensIOP = Intraocular pressurelogMAR = Logarithm of the minimum angle of resolutionPCIOL = Posterior chamber intraocular lensscleral fixationSD = Standard deviationSFIOL = Scleral-fixated intraocular lenssuture techniques

Identifiers

PMID42572606
PMCPMC13453117

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.