Evidence map›Paper›PMID 42571210›Full record

ArticleCase reports in dentistry2026

A 4-mm-Short Implant Rehabilitation in the Posterior Maxilla With Dynamic Navigation Technology: A Case Report After 10 Years of Postloading Follow-Up.

Gerardo Pellegrino, Fabio Rossi, Andrea Oliverio, Subhi Tayeb, Claudia Angelino, Carlo Barausse, Pietro Felice

Abstract read
In one paragraph

Article in Case reports in dentistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Gerardo PellegrinoUnit of Oral Surgery, Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy, unibo.it.
Fabio RossiPrivate Practice, Bologna, Italy.
Andrea OliverioUnit of Oral Surgery, Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy, unibo.it.
Subhi TayebUnit of Oral Surgery, Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy, unibo.it.ORCID https://orcid.org/0009-0009-3346-7057
Claudia AngelinoUnit of Oral Surgery, Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy, unibo.it.ORCID https://orcid.org/0009-0006-2700-9066
Carlo BarausseUnit of Oral Surgery, Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy, unibo.it.
Pietro FeliceUnit of Oral Surgery, Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy, unibo.it.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Implant rehabilitation in the posterior maxilla with severe vertical bone atrophy remains clinically challenging, particularly when bone augmentation procedures are not feasible or are refused by the patient. The use of ultrashort implants combined with dynamic navigation has been proposed as a minimally invasive alternative in selected cases; however, long-term clinical evidence in the maxilla is still limited. This case report describes the 10-year clinical and radiographic outcomes of a single 4-mm ultrashort implant placed in the posterior maxilla using dynamic navigation technology. A 47-year-old nonsmoking female patient presented with a single edentulous maxillary first molar and severe vertical bone resorption (≤ 5 mm). The patient declined bone augmentation and fixed partial denture therapy. Implant placement was planned and performed under dynamic navigation guidance, followed by restoration with a single implant-supported crown. Clinical and radiographic follow-up was conducted regularly up to 10 years after prosthetic loading. Throughout the follow-up period, no biological or prosthetic complications were observed. Peri-implant soft tissues remained healthy, with no bleeding on probing or suppuration. Radiographic evaluation using standardized periapical radiographs revealed a mean marginal bone loss of 0.35 mm at 10 years. The implant-supported crown maintained stable function and structural integrity, and the patient reported high satisfaction with the treatment outcome. Within the limitations of a single case report, these findings suggest that the combination of dynamic navigation and ultrashort implants may represent a reliable and minimally invasive treatment option for single implant rehabilitation in severely atrophic posterior maxillary sites. Further prospective studies with larger sample sizes and long-term follow-up are required to confirm the predictability and reproducibility of this approach.

Indexed as

case reportdynamic navigationlong-term follow-upposterior maxillashort dental implants

Identifiers

PMID42571210
PMCPMC13451833

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.