Evidence map›Paper›PMID 42571003›Full record

ArticleBMC health services research2026

Characterisation and management of therapy-interrupting system errors associated with the use of the HomeChoice cycler for automated peritoneal dialysis.

Annemarie Albert, Stefan Richter, Rainer Peter Woitas, Philipp Stieger, Rüdiger C Braun-Dullaeus, Christian Albert

Abstract read
In one paragraph

Article in BMC health services research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Annemarie AlbertDiaverum Renal Services, Am Neuen Garten 11, 14469, Potsdam, Germany.ORCID http://orcid.org/0000-0002-5611-1506
Stefan RichterDiaverum Renal Services, Am Neuen Garten 11, 14469, Potsdam, Germany.
Rainer Peter WoitasDiaverum Deutschland GmbH, Hansastraße 23, 80686, München, Deutschland.
Philipp StiegerUniversity Clinic for Cardiology and Angiology, Otto‑von‑Guericke University Magdeburg, Leipziger Str.44, 39120, Magdeburg, Germany.ORCID http://orcid.org/0000-0001-6103-9038
Rüdiger C Braun-DullaeusUniversity Clinic for Cardiology and Angiology, Otto‑von‑Guericke University Magdeburg, Leipziger Str.44, 39120, Magdeburg, Germany.ORCID http://orcid.org/0000-0003-3888-6532
Christian AlbertDiaverum Renal Services, Am Neuen Garten 11, 14469, Potsdam, Germany. Christian.Albert@med.ovgu.de.ORCID http://orcid.org/0000-0002-6956-9962

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMethodological and technical education of nurses is required to address challenges of technology integration in peritoneal dialysis (PD). We analysed the nature of therapy interrupting system errors in automated peritoneal dialysis (APD) cyclers of a German PD reference care centre and provide applicable resolution proposals.

methodsWe documented therapy interrupting system errors of HomeChoice Pro and HomeChoice Claria cyclers (Baxter, BX, Unterschleißheim, Germany) including the years 2015-2023. We systematically characterise and suggest resolution strategies to these errors based on routinely collected health data and user experience to safely guide nephrology professionals and patients during troubleshooting. The 'reporting of studies conducted using observational routinely collected health data' (RECORD)-statement was considered.

resultsWe identified 49 different therapy interrupting system errors which were assigned to eight major categories: Errors associated to the pressure chamber (N=18), the Digitalboard/EEPROM (N=18, Electrically Erasable Programmable Read Only Memory), air in set (N=3), opening of the set's door (N=3), those associated to the energy system (N=3), the heater system (N=3) and a variety of errors resulting in an abrupt termination or non-commencement of the treatment session without clear group assignment (undefined, N=1) or without sufficient documentation. In total, 138 error incidents were documented during the observational timeframe. In frequential order errors were attributed to the pressure chamber (21.74%,), and air in set (19.57%) where specifically error 2240 occurred in 17.39% of total cases, the Digitalboard/EEPROM (17.39%), the energy or battery (16.67%; No. 1032 in 19/23 cases), the set's door (7.25%) and the heater (4.35%). In 17 cases (12.32%) no error number was documented by the patient or staff. One error cause was registered as undefined (0.72%). Overall, errors were rarely occurring in <0.25% of treatment sessions performed in the observational timeframe.

conclusionThese findings may be useful to guide training purposes for nephrology personnel and persons doing APD. For the manufacturer, the information provided may be helpful to improve error management and information transmission to the persons doing APD with the HomeChoice devices.

Indexed as

Medical ErrorsPeritoneal DialysisEquipment FailureGermanyHumansAPDAutomated peritoneal dialysisCyclerHomeChoiceHome therapyNursingPeritoneal dialysisRenal replacement therapyTelemedicine

Identifiers

PMID42571003
PMCPMC13452097

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.