Evidence map›Paper›PMID 42568759›Full record

ArticleJournal of ophthalmology2026

One-Year Outcome of Vitreous Cortex Remnants Removal Using a Nitinol Flex Loop for Recurrent Retinal Detachment Patients.

Zhan Xie, Yifan Lin, Haiyue Xie, Mulong Du, Hongfei Xu, Ping Xie

Abstract read
In one paragraph

Article in Journal of ophthalmology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Zhan XieDepartment of Ophthalmology, The First Affiliated Hospital of Nanjing Medical University, Nanjing 210029, Jiangsu, China, njmu.edu.cn.ORCID https://orcid.org/0000-0003-3322-0029
Yifan LinDepartment of Ophthalmology, The First Affiliated Hospital of Nanjing Medical University, Nanjing 210029, Jiangsu, China, njmu.edu.cn.ORCID https://orcid.org/0009-0009-4193-1024
Haiyue XieDepartment of Ophthalmology, The First Affiliated Hospital of Nanjing Medical University, Nanjing 210029, Jiangsu, China, njmu.edu.cn.ORCID https://orcid.org/0000-0003-4982-7810
Mulong DuDepartment of Biostatistics, School of Public Health, Nanjing Medical University, Nanjing 210029, Jiangsu, China, njmu.edu.cn.ORCID https://orcid.org/0000-0002-2733-6490
Hongfei XuDepartment of Ophthalmology, Jurong Hospital Affiliated to Jiangsu University, Zhenjiang 212400, China.
Ping XieDepartment of Ophthalmology, The First Affiliated Hospital of Nanjing Medical University, Nanjing 210029, Jiangsu, China, njmu.edu.cn.ORCID https://orcid.org/0000-0003-4257-8970

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To evaluate the 1-year outcome of vitreous cortex remnants (VCRs) removal using a nitinol flex loop during pars plana vitrectomy (PPV) in the treatment of recurrent retinal detachment (rRD). Patients and Methods: A total of 95 eyes from 95 patients with rRD with the intraoperative evidence of VCRs were retrospectively analyzed at the First Affiliated Hospital of Nanjing Medical University. Vitreous visualization was enhanced with triamcinolone. The presence of VCRs was determined by gently scraping the retinal surface with a disposable nitinol loop. Patients were divided into two groups: conventional PPV with the aid of vitrectomy probe and intraocular forceps between January 2022 and December 2022 (Group A, 41 eyes), and PPV assisted by the FINESSE Flex loop for VCRs removal between January 2023 and December 2023 (Group B, 54 eyes). Outcomes were assessed during follow-ups at postoperative 1 week, 1 month, 3 months, 6 months, and 12 months. Primary outcomes included vitrectomy duration, single-surgery anatomic success rate, intraoperative and postoperative complications, and best-corrected visual acuity (BCVA). Results: Group B had a significantly shorter vitrectomy duration compared to Group A ( Conclusion: Use of the FINESSE Flex loop during PPV for rRD allows a shorter surgical duration, a lower incidence of iatrogenic retinal breaks, and a higher single-surgery anatomic success rate, without increasing postoperative complications.

Indexed as

FINESSE Flex loopmembrane scraperpars plana vitrectomyrecurrent retinal detachmentvitreous cortex

Identifiers

PMID42568759
PMCPMC13447967

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.