Evidence map›Paper›PMID 42565456›Full record

ArticleJournal of synchrotron radiation2026

One million scans later: the evolution of the I16 material and magnetism beamline at Diamond Light Source.

Aly H Abdeldaim, Rebecca Scatena, James Hawkins, Gareth Nisbet, Daniel G Porter, Graeme Barlow, Andy Marshall, Brian Nutter, Guillaume Beutier, Stephen P Collins and 1 more

Abstract read
In one paragraph

Article in Journal of synchrotron radiation, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Aly H AbdeldaimDiamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire, United Kingdom.ORCID 0000-0001-8417-7441
Rebecca ScatenaDiamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire, United Kingdom.
James HawkinsDiamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire, United Kingdom.
Gareth NisbetDiamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire, United Kingdom.ORCID 0000-0003-2314-5862
Daniel G PorterDiamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire, United Kingdom.ORCID 0000-0002-9397-7835
Graeme BarlowDiamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire, United Kingdom.
Andy MarshallDiamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire, United Kingdom.
Brian NutterDiamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire, United Kingdom.
Guillaume BeutierDiamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire, United Kingdom.ORCID 0000-0001-6064-0139
Stephen P CollinsDiamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire, United Kingdom.ORCID 0000-0001-5120-0764
Alessandro BombardiDiamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire, United Kingdom.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Here, we review the capabilities of beamline I16 at Diamond Light Source after nearly 20 years of operation and continuous development. I16 is an X-ray scattering beamline operating in the 2.46-16 keV energy range with energy scans with a resolution of 1 meV. The beamline is equipped with a six-circle kappa diffractometer, offering flexible experimental geometries and support for a variety of ancillary equipment. Available equipment includes cryostats and cryofurnaces that span temperatures from 4.2 K to 700 K, which can be combined with applied electric fields, permanent magnets up to 1 T, and uniaxial strain cells. A range of detectors is mounted on the diffractometer arm, including a photon-counting area detector and an avalanche photodiode, both compatible with crystal analyzers for polarization analysis. Diamond single-crystal phase retarders provide full control of the incident X-ray polarization. These capabilities establish I16 as a state-of-the-art instrument for resonant and non-resonant X-ray scattering, multi Bragg coherent diffraction imaging, and grazing-incidence small- and wide-angle X-ray scattering. Together, they allow for studies of complex electronic, magnetic and structural phenomena in single crystals and thin films. We also outline the software infrastructure supporting experiment planning, data acquisition and rapid on-the-fly data analysis, and discuss ongoing developments and the anticipated benefits of the upgrade to a fourth-generation source.

Indexed as

BCDIGI-WAXSNRXSREXSX-ray beamline

Identifiers

PMID42565456
PMCPMC13549327

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.