Evidence map›Paper›PMID 42564439›Full record

ArticleInternational journal of biomedical imaging2026

Automated Semisupervised Measurement of Optic Nerve Sheath Diameter From CT Following Traumatic Brain Injury.

Emily Wittrup, Alan Kay, Elizabeth Lombard, Jett Rosen, Ethan Schnathorst, Christine Geng, Haoyuan Ma, Erica B Stein, Kevin R Ward, Craig Williamson and 1 more

Abstract read
In one paragraph

Article in International journal of biomedical imaging, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Emily WittrupGilbert S. Omenn Department of Computational Medicine and Bioinformatics, University of Michigan, Ann Arbor, Michigan, USA, umich.edu.ORCID https://orcid.org/0000-0002-5314-5903
Alan KayGilbert S. Omenn Department of Computational Medicine and Bioinformatics, University of Michigan, Ann Arbor, Michigan, USA, umich.edu.ORCID https://orcid.org/0009-0000-5056-5104
Elizabeth LombardGilbert S. Omenn Department of Computational Medicine and Bioinformatics, University of Michigan, Ann Arbor, Michigan, USA, umich.edu.
Jett RosenGilbert S. Omenn Department of Computational Medicine and Bioinformatics, University of Michigan, Ann Arbor, Michigan, USA, umich.edu.ORCID https://orcid.org/0009-0002-5912-3788
Ethan SchnathorstGilbert S. Omenn Department of Computational Medicine and Bioinformatics, University of Michigan, Ann Arbor, Michigan, USA, umich.edu.ORCID https://orcid.org/0009-0007-2905-2145
Christine GengGilbert S. Omenn Department of Computational Medicine and Bioinformatics, University of Michigan, Ann Arbor, Michigan, USA, umich.edu.
Haoyuan MaGilbert S. Omenn Department of Computational Medicine and Bioinformatics, University of Michigan, Ann Arbor, Michigan, USA, umich.edu.
Erica B SteinDepartment of Radiology, Michigan Medicine, Ann Arbor, Michigan, USA, umich.edu.ORCID https://orcid.org/0000-0002-7339-8107
Kevin R WardDepartment of Emergency Medicine, Michigan Medicine, Ann Arbor, Michigan, USA, umich.edu.ORCID https://orcid.org/0000-0001-5939-409X
Craig WilliamsonMax Harry Weil Institute for Critical Care Research and Innovation, Michigan Medicine, Ann Arbor, Michigan, USA, umich.edu.
Kayvan NajarianGilbert S. Omenn Department of Computational Medicine and Bioinformatics, University of Michigan, Ann Arbor, Michigan, USA, umich.edu.ORCID https://orcid.org/0000-0003-4485-6612

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Automated measurement of optic nerve sheath diameter (ONSD) from computed tomography (CT) scans is clinically important, but deep learning methods are often limited by the scarcity of high-quality, expert-labeled data given the labor-intensive nature of manual segmentations. To address this, we present a fully automated modular pipeline combining deep learning and semisupervised learning techniques for ONSD estimation from axial head CT scans. The pipeline features three stages: (1) deep learning-based slice selection, (2) semisupervised machine learning for optic nerve segmentation utilizing both labeled and unlabeled publicly available data, and (3) geometric and morphological ONSD measurement. When validated on public and internal datasets, our approach generalized better than traditional supervised segmentation methods, achieving an intersection over union (IoU) of 0.561 ± 0.141 and Dice coefficient of 0.707 ± 0.131 on previously unseen data. Slice-wise measurement accuracy varied based on measurement distance from the ocular globe, yielding mean absolute errors as low as 1.779 and 1.899 mm for the right and left ONSD, respectively. Our findings highlight the potential for semisupervised deep learning to deliver fully automated ONSD measurements and the framework's adaptability to difficult medical imaging tasks even with limited, low-quality ground truth for training.

Indexed as

artificial intelligenceCToptic nervesemisupervised learningtraumatic brain injury

Identifiers

PMID42564439
PMCPMC13442929

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.