Evidence map›Paper›PMID 42564256›Full record

ArticleFrontiers in public health2026

Evaluating a rapid fit-testing method for N95 respirators in Chinese healthcare workers: a paired crossover simulation and diagnostic agreement study.

Guo Jing Han, Lina Li, Ru Fan, Wei Li, Zhao Jun Sheng, Wei Hua Zhang

Erratum issuedAbstract read
In one paragraph

Article in Frontiers in public health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

Guo Jing HanDepartment of Respiratory and Critical Care Medicine, the First Medical Centre of Chinese PLA General Hospital, Beijing, China.
Lina LiDepartment of Respiratory and Critical Care Medicine, the First Medical Centre of Chinese PLA General Hospital, Beijing, China.
Ru FanDepartment of Respiratory and Critical Care Medicine, the First Medical Centre of Chinese PLA General Hospital, Beijing, China.
Wei LiBeijing SINOVO Times Technology Co. Ltd., Beijing, China.
Zhao Jun ShengDepartment of Respiratory and Critical Care Medicine, the First Medical Centre of Chinese PLA General Hospital, Beijing, China.
Wei Hua ZhangDepartment of Respiratory and Critical Care Medicine, the Eighth Medical Center of Chinese PLA General Hospital, Beijing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: China lacks standardized rapid fit-testing protocols for N95 respirators. This exploratory study assessed the feasibility between the OSHA 2.5-min quantitative fit-testing protocol and the 6-min Chinese reference protocol among Chinese healthcare workers, also assessing mask seal degradation during chest compressions. Methods: A total of 54 nurses and physicians were recruited for this paired crossover simulation and diagnostic agreement study. Participants underwent quantitative fit testing using two N95 respirator models: D918 (a foldable respirator) and D920 (a cup-type respirator). Fit-test outcomes obtained using the 2.5-min protocol were compared with those obtained using the 6-min reference protocol. Paired pass results were analyzed using McNemar's test, and agreement was assessed using Cohen's kappa with 95% confidence intervals. Diagnostic indices, including sensitivity, specificity, positive predictive value, negative predictive value, and likelihood ratios, were calculated from raw 2 × 2 contingency tables. Seal integrity during simulated chest compressions was also evaluated. Results: Using the 6-min protocol as the reference, the D918 respirator showed pass rates of 75.93% [95%CI, 0.63 to 0.85] for the 2.5-min protocol and 81.48% [95%CI, 0.69 to 0.90] for the 6-min protocol. The corresponding sensitivity, specificity, PPV, PLR, and NLR were 97.56% [95%CI, 0.85 to 1.00], 69.23% [95%CI, 0.39 to 0.90], and 90.9% [95%CI, 0.77 to 0.97], 3.17 [95%CI, 1.40 to 7.18] and 0.03 [95%CI, 0.00 to 0.26], respectively. For the D920 respirator, pass rates were 92.59% [95%CI, 0.82 to 0.97] and 94.44% [95%CI, 0.85 to 0.99] for the 2.5-min and 6-min protocols, respectively, with sensitivity, specificity, PPV, PLR and NLR of 100% [95%CI, 0.91 to 1.00], 75% [95%CI, 0.22 to 0.99], 94.4% [95%CI, 0.84 to 0.99], 4.00 [95%CI, 0.73 to 21.84] and 0.02 [95%CI, 0 to not estimable]. During CC, baseline seal integrity was achieved in 98.15% of participants. The D918 showed clinically significant leakage during (44.44%) and post-compression (29.63%), contrasting with D920's maintained performance ( Conclusion: In this exploratory paired simulation study, the OSHA 2.5-min protocol showed preliminary agreement with the 6-min Chinese reference protocol for quantitative N95 respirator fit testing among Chinese healthcare workers, particularly for the D920 respirator. However, the study does not establish formal equivalence or non-inferiority. Larger multicenter studies with prespecified non-inferiority margins are needed before the rapid protocol can be recommended as a replacement for the standard 6-min protocol.

Indexed as

Health PersonnelN95 RespiratorsOccupational ExposureAdultChinaCross-Over StudiesEquipment DesignFemaleHumansMaleSensitivity and Specificitychest compressionsfit testinghealthcare workersN95 respiratorsrapid-test protocol

Identifiers

PMID42564256
PMCPMC13442521

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.